Comparing myopic error in patients with basic and convergence insufficiency intermittent exotropia in China
- PMID: 37365512
- PMCID: PMC10294520
- DOI: 10.1186/s12886-023-03043-8
Comparing myopic error in patients with basic and convergence insufficiency intermittent exotropia in China
Abstract
Purpose: To compare the degree of myopia between the dominant and non-dominant eyes in teenagers with intermittent exotropia (IXT) in China.
Methods: A total of 199 IXT patients with myopia were included in this retrospective study and were divided into two groups according to the difference between near and distance exodeviation: basic IXT and convergence insufficiency (CI) IXT. Refractive errors were analyzed by spherical equivalent (SE) values. Patients were further stratified into anisometropia group and non-anisometropia group based on binocular SE values difference greater than 1.0D or not.
Results: There were 127 patients in the CI IXT group, with a near deviation of 46.94 ± 20.53 prism diopters (PD) and a distance deviation of 28.36 ± 14.34 PD, and there were 72 (36.2%) patients in the basic IXT group, with a near deviation of 37.68 ± 22.21 PD and a distance deviation angle of 33.21 ± 23.96 PD. The near exodeviation was significantly larger in the CI group than in the basic IXT group(P < 0.001). In the CI IXT group, the mean SE was - 2.09 ± 1.45 diopters (D) in the dominant eye and - 2.53 ± 1.44D in the non-dominant eye, while in the basic IXT group, the mean SE was - 2.46 ± 1.56D in the dominant eye and - 2.89 ± 1.37D in the non-dominant eye. The anisometropia group included 43 patients, while non-anisometropia group included 156 patients. The near and distance exodeviation in the anisometropia group were 45.26 ± 24.41 PD and 33.53 ± 23.31 PD, respectively, and those in the non-anisometropia group were 43.42 ± 20.69 PD and 29.07 ± 16.84 PD, respectively. There were no significant differences in near and distance deviation (P = 0.78 and P = 0.73 respectively) between the two groups. The SE of the dominant eye was less myopic than of the non-dominant eyes in both the CI and anisometropia groups (P = 0.002 and P < 0.001, respectively).
Conclusions: Our study revealed that convergence insufficiency IXT is more common than the basic type in pediatric myopic population and is characterized by higher inter-eye differences of myopia. The dominant eye was found to be less myopic in IXT patients, particularly in those with convergence insufficiency and anisometropia.
Keywords: Anisometropia; Convergence insufficiency; Intermittent exotropia; Myopia; Ocular dominance.
© 2023. The Author(s).
Conflict of interest statement
The authors declare that they have no competing interests.
Similar articles
-
Refractive Profile of Surgical Patients with Intermittent Exotropia: A Large-Sample Cross-Sectional Study in Southern China.Curr Eye Res. 2023 Dec;48(12):1133-1143. doi: 10.1080/02713683.2023.2255396. Epub 2023 Sep 5. Curr Eye Res. 2023. PMID: 37669912
-
Difference in myopia progression between dominant and non-dominant eye in patients with intermittent exotropia.Graefes Arch Clin Exp Ophthalmol. 2020 Jun;258(6):1327-1333. doi: 10.1007/s00417-020-04700-0. Epub 2020 Apr 19. Graefes Arch Clin Exp Ophthalmol. 2020. PMID: 32307585
-
0.01% Atropine Eye Drops in Children With Myopia and Intermittent Exotropia: The AMIXT Randomized Clinical Trial.JAMA Ophthalmol. 2024 Aug 1;142(8):722-730. doi: 10.1001/jamaophthalmol.2024.2295. JAMA Ophthalmol. 2024. PMID: 38958962 Free PMC article. Clinical Trial.
-
[Intermittent exotropia].J Fr Ophtalmol. 2019 Nov;42(9):1007-1019. doi: 10.1016/j.jfo.2018.12.031. Epub 2019 Jul 10. J Fr Ophtalmol. 2019. PMID: 31301849 Review. French.
-
Divergence excess and basic exotropia types of intermittent exotropia: a major review. Part 1: prevalence, classification, risk factors, natural history and clinical characteristics.Strabismus. 2023 Jun;31(2):97-128. doi: 10.1080/09273972.2023.2227681. Epub 2023 Jul 25. Strabismus. 2023. PMID: 37489263 Review.
Cited by
-
Binocular Summation With Quantitative Contrast Sensitivity Function: A Novel Parameter to Evaluate Binocular Function in Intermittent Exotropia.Invest Ophthalmol Vis Sci. 2024 Jan 2;65(1):3. doi: 10.1167/iovs.65.1.3. Invest Ophthalmol Vis Sci. 2024. PMID: 38165705 Free PMC article.
References
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Medical