. 2023 Aug 1;39(8):608-611.
doi: 10.1097/PEC.0000000000003004. Epub 2023 Jul 1.

Safely Reducing Unnecessary Radiographs in Suspected Pediatric Musculoskeletal Injuries: A Multidisciplinary Developed Algorithm

Affiliations

Safely Reducing Unnecessary Radiographs in Suspected Pediatric Musculoskeletal Injuries: A Multidisciplinary Developed Algorithm

Sarah Lander et al. Pediatr Emerg Care. .

Abstract

Background: While radiographs are a critical component of diagnosing musculoskeletal (MSK) injuries, they are associated with radiation exposure, patient discomfort, and financial costs. Our study initiative was to develop a system to diagnose pediatric MSK injuries efficiently while minimizing unnecessary radiographs.

Methods: This was a quality improvement trial performed prospectively at a single level one trauma center. A multidisciplinary team with leaders from pediatric orthopedics, trauma surgery, emergency medicine, and radiology created an algorithm delineating which x-rays should be obtained for pediatric patients presenting with MSK injuries. The intervention was performed in the following 3 stages: stage 1: retrospective validation of the algorithm, stage 2: implementation of the algorithm, and stage 3: sustainability evaluation. Outcomes measured included number of extra radiographs per pediatric patient and any missed injuries.

Results: In stage 1, 295 patients presented to the pediatric emergency department with MSK injuries. A total of 2148 radiographs were obtained, with 801 not indicated per the protocol, for an average of 2.75 unnecessary radiographs per patient. No injuries would have been missed using the protocol. In stage 2, 472 patients had 2393 radiographs with 339 not indicated per protocol, averaging 0.72 unnecessary radiographs per patient, a significant reduction from stage 1 ( P < 0.001). There were no missed injuries identified on follow-up. In stage 3, improvement was sustained for the subsequent 8 months with an average of 0.34 unnecessary radiographs per patient ( P < 0.05).

Conclusions: Sustained reduction of unnecessary radiation to pediatric patients with suspected MSK injuries was accomplished through the development and implementation of a safe and effective imaging algorithm. The multidisciplinary approach, widespread education of pediatric providers, and standardized order sets improved buy-in and is generalizable to other institutions.Level of Evidence: III.

PubMed Disclaimer

Conflict of interest statement

Disclosure: The authors declare no conflict of interest.

References

    1. Prasad KN, Cole WC, Hasse GM. Health risks of low dose ionizing radiation in humans: a review. Exp Biol Med (Maywood) . 2004;229:378–382.
    1. National Research Council. Health Risks From Exposure to Low Levels of Ionizing Radiation: BEIR VII Phase 2 . Washington, DC: National Academies Press; 2006.
    1. Doody MM, Lonstein JE, Stovall M, et al. Breast cancer mortality after diagnostic radiography: findings from the U.S. Scoliosis Cohort Study. Spine . 2000;25:2052–2063.
    1. Boice JD Jr., Monson RR. Breast cancer in women after repeated fluoroscopic examinations of the chest. J Natl Cancer Inst . 1977;59:823–832.
    1. Howe GR, Miller AB, Sherman GJ. Breast cancer mortality following fluoroscopic irradiation in a cohort of tuberculosis patients. Cancer Detect Prev . 1982;5:175–178.

LinkOut - more resources