Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Sep;415(22):5539-5550.
doi: 10.1007/s00216-023-04828-y. Epub 2023 Jul 4.

A downstream process control tool based on the redox dye resazurin for rapid and accurate measurement of microbial metabolic activity

Affiliations

A downstream process control tool based on the redox dye resazurin for rapid and accurate measurement of microbial metabolic activity

Arkadeep Mukherjee et al. Anal Bioanal Chem. 2023 Sep.

Abstract

Many sophisticated water treatment plants need a reliable, fast, and economical microbial load detection method. We refined a colorimetric assay using the redox dye resazurin to assess viable microorganisms. Here, we have used a mixed bacterial suspension of significant multi-drug-resistant coliform bacteria isolated from hospital wastewater and constructed a resazurin reduction calibration curve which could accurately predict the level of microbial contamination. The number of viable microorganisms was calculated from calibration curve in terms of log colony forming units (CFU) per milliliter. Ultrasonication disinfection of bacterial suspension for a duration of 50 min measured by resazurin assay depicted a reduction of 16.94%, 26.48%, and 37.69% at 410 W, 580 W, and 700 W, respectively. A synergistic effect of the combined methods of ultrasonication and heat disinfection treatments on raw wastewater and secondary wastewater effluent was observed and was also evaluated using both resazurin assay and standard plate count method. For raw wastewater, about 1.8 log reduction was observed for ultrasonication alone and 4 log CFU/mL reduction for thermosonication. In the secondary wastewater effluent, a reduction of 2.9 and 3.2 log CFU/mL was recorded for ultrasonication and thermosonication respectively. Resazurin microbial viability test results were highly comparable with conventional colony plate count for all treatment procedures, suggesting its appropriateness for quick and reliable wastewater sample microbial viability monitoring.

Keywords: Colorimetric; Resazurin; Secondary effluent; Thermosonication; Wastewater treatment.

PubMed Disclaimer

Similar articles

References

    1. Sathya R, Arasu MV, Al-Dhabi NA, Vijayaraghavan P, Ilavenil S, Rejiniemon TS. Towards sustainable wastewater treatment by biological methods – a challenges and advantages of recent technologies. Urban Clim. 2023;47:101378. https://doi.org/10.1016/j.uclim.2022.101378.
    1. Bizzi CA, Zanatta RC, Santos D, Giacobe K, Dallago RM, Mello PA, et al. Ultrasound-assisted extraction of chromium from residual tanned leather: an innovative strategy for the reuse of waste in tanning industry. Ultrason Sonochem. 2020;64:104682. https://doi.org/10.1016/j.ultsonch.2019.104682.
    1. Ryecroft S, Shaw A, Fergus P, Kot P, Hashim K, Moody A, et al. A first implementation of underwater communications in raw water using the 433 MHz frequency combined with a bowtie antenna. Sensors [Internet]. 2019; 19(8).
    1. Alattabi AW, Harris C, Alkhaddar R, Alzeyadi A, Hashim K. Treatment of residential complexes’ wastewater using environmentally friendly technology. Procedia Eng. 2017;196:792–9. https://doi.org/10.1016/j.proeng.2017.08.009 . - DOI
    1. Hashim KS, Shaw A, Al Khaddar R, Pedrola MO, Phipps D. Energy efficient electrocoagulation using a new flow column reactor to remove nitrate from drinking water – experimental, statistical, and economic approach. J Environ Manage. 2017;196:224–33. https://doi.org/10.1016/j.jenvman.2017.03.017 . - DOI - PubMed

LinkOut - more resources