Practical applications of vitreous imaging for the treatment of vitreous opacities with YAG vitreolysis
- PMID: 37402010
- DOI: 10.1007/s10792-023-02765-4
Practical applications of vitreous imaging for the treatment of vitreous opacities with YAG vitreolysis
Abstract
Purpose: To demonstrate the methodology and efficacy of using scanning laser ophthalmoscopy (SLO) and dynamic optical coherence tomography (OCT) to identify and treat symptomatic vitreous floaters using yttrium-aluminum garnet laser vitreolysis (YLV).
Methods: This is a case series highlighted from a cross sectional retrospective study conducted at the Vitreous Retina Macula Specialists of Toronto. Forty eyes from thirty-five patients were treated with YLV between November 2018 and December 2020 for symptomatic floaters and imaged with SLO and dynamic OCT. Patients were re-treated with YLV if they reported ongoing significant vision symptoms during follow-up which correlated to visible opacities on exam and or imaging. Three cases will be highlighted to present the practical applications of SLO and dynamic OCT imaging for YLV treatment.
Results: Forty treated eyes were enrolled in this study, with twenty-six eyes (65%) requiring at least one repeat YLV treatment following the first treatment due to ongoing symptomatic floaters. Following the first YLV, there was a significant improvement in overall mean best corrected visual acuity compared to before treatment (0.11 ± 0.20 LogMAR units vs. 0.14 ± 0.20 LogMAR units, p = 0.02 (paired t test)). Case 1 demonstrates a dense, solitary vitreous opacity that has been localized with dynamic OCT imaging to track its movements and retinal shadowing with the patient's eye movements. Case 2 shows the utility of adjusting the fixation target to monitor the movement of vitreous opacities in real-time. Case 3 exhibits an association between decreased symptom burden and vitreous opacity density after YLV.
Conclusion: Image-guided YLV facilitates the localization and confirmation of vitreous opacities. SLO and dynamic OCT of the vitreous can provide a real-time evaluation of floater size, movement, and morphology, to help clinicians target treatment and monitoring of symptomatic floaters.
Keywords: Dynamic OCT; Floaters; OCT; Scanning laser ophthalmoscopy; Vitreolysis; YAG laser.
© 2023. The Author(s), under exclusive licence to Springer Nature B.V.
References
-
- Luo J, An X, Kuang Y (2018) Efficacy and safety of yttrium-aluminium garnet (YAG) laser vitreolysis for vitreous floaters. J Int Med Res 46:4465–4471. https://doi.org/10.1177/0300060518794245 - DOI - PubMed - PMC
-
- Singh IP (2018) Novel OCT application and optimized YAG laser enable visualization and treatment of mid- to posterior vitreous floaters. Ophthal Surg Lasers Imaging Retin 49:806–811. https://doi.org/10.3928/23258160-20181002-10 - DOI
-
- Shah CP, Heier JS (2017) YAG laser vitreolysis vs sham YAG vitreolysis for symptomatic vitreous floaters. JAMA Ophthalmol 135:918. https://doi.org/10.1001/jamaophthalmol.2017.2388 - DOI - PubMed - PMC
-
- Sebag J, Yee KMP, Wa CA et al (2014) Vitrectomy for floaters: prospective efficacy analyses and retrospective safety profile. Retina 34:1062–1068. https://doi.org/10.1097/IAE.0000000000000065 - DOI - PubMed
-
- Zou H, Liu H, Xu X, Zhang X (2013) The impact of persistent visually disabling vitreous floaters on health status utility values. Qual Life Res 22:1507–1514. https://doi.org/10.1007/s11136-012-0256-x - DOI - PubMed
MeSH terms
LinkOut - more resources
Full Text Sources