Meta-Analysis
. 2023 May-Jun;38(suppl):30-36.
doi: 10.11607/jomi.10500.

Ceramic Dental Implants: A Systematic Review and Meta-analysis

Meta-Analysis

Ceramic Dental Implants: A Systematic Review and Meta-analysis

Jörg Neugebauer et al. Int J Oral Maxillofac Implants. 2023 May-Jun.

Abstract

Purpose: To evaluate the performance of one- and two-piece ceramic implants regarding implant survival and success and patient satisfaction. Materials and Methods: This review followed the PRISMA 2020 guidelines using PICO format and analyzed clinical studies of partially or completely edentulous patients. The electronic search was conducted in PubMed/MEDLINE using Medical Subject Headings (MeSH) keywords related to dental zirconia ceramic implants, and 1,029 records were received for detailed screening. The data obtained from the literature were analyzed by single-arm, weighted meta-analyses using a random-effects model. Forest plots were used to synthesize pooled means and 95% CI for the change in marginal bone level (MBL) for short-term (1 year), mid-term (2 to 5 years), and long-term (over 5 years) follow-up time intervals. Results: Among the 155 included studies, the case reports, review articles, and preclinical studies were analyzed for background information. A meta-analysis was performed for 11 studies for one-piece implants. The results indicated that the MBL change after 1 year was 0.94 ± 0.11 mm, with a lower bound of 0.72 and an upper bound of 1.16. For the mid term, the MBL was 1.2 ± 0.14 mm with a lower bound of 0.92 and an upper bound of 1.48. For the long term, the MBL change was 1.24 ± 0.16 mm with a lower bound of 0.92 and an upper bound of 1.56. Conclusion: Based on this literature review, one-piece ceramic implants achieve osseointegration similar to titanium implants, with a stable MBL or a slight bone gain after an individual initial design depending on crestal remodeling. The risk of implant fracture is low for current commercially available implants. Immediate loading or temporization of the implants does not interfere with the course of osseointegration. Scientific evidence for two-piece implants is rare.

PubMed Disclaimer

Substances

LinkOut - more resources