Contact Dermatitis to Diabetes Medical Devices
- PMID: 37445875
- PMCID: PMC10341568
- DOI: 10.3390/ijms241310697
Contact Dermatitis to Diabetes Medical Devices
Abstract
Skin adverse reactions to diabetes medical devices have been reported frequently over recent years. Adhesives attaching glucose sensors and continuous insulin infusion sets to the skin are proven to cause both allergic contact dermatitis and irritant contact dermatitis in patients with diabetes mellitus. Several allergens contained in adhesives and/or parts of medical devices are documented to cause allergic contact dermatitis, with acrylate chemicals being the most common culprit-especially isobornyl acrylate (IBOA), but also 2,2'-methylenebis(6-tert-butyl-4-methylphenol) monoacrylate or cyanoacrylates. Epoxy resin, colophonium and nickel were also identified as causative allergens. However, repetitive occlusion, maceration of the skin and resulting disruption of the skin barrier seem to have an impact on the development of skin lesions as well. The purpose of this study is to highlight the burden of contact dermatitis triggered by diabetes medical devices and to show possible mechanisms responsible for the development of contact dermatitis in a group of diabetic patients.
Keywords: 2,2′-methylenebis(6-tert-butyl-4-methylphenol) monoacrylate; IBOA; MBPA; allergic contact dermatitis; diabetes medical devices; glucose sensors; insulin pumps; irritant contact dermatitis; isobornyl acrylate.
Conflict of interest statement
The authors declare no conflict of interest.
Figures
Similar articles
-
Adverse cutaneous reaction to diabetic glucose sensors and insulin pumps: Irritant contact dermatitis or allergic contact dermatitis?Contact Dermatitis. 2020 Jul;83(1):25-30. doi: 10.1111/cod.13529. Epub 2020 May 4. Contact Dermatitis. 2020. PMID: 32212168
-
Role of acrylates in the development of contact dermatitis in diabetic patients-A Polish dermatology tertiary centre experience.Contact Dermatitis. 2024 Feb;90(2):126-133. doi: 10.1111/cod.14436. Epub 2023 Oct 15. Contact Dermatitis. 2024. PMID: 37840370
-
Further Evidence of Allergic Contact Dermatitis Caused by 2,2'-Methylenebis(6- tert -Butyl-4-Methylphenol) Monoacrylate, a New Sensitizer in the Dexcom G6 Glucose Sensor.Dermatitis. 2022 Jul-Aug 01;33(4):287-292. doi: 10.1097/DER.0000000000000767. Dermatitis. 2022. PMID: 34115662
-
Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 1: Sensors and pumps, adverse cutaneous reactions, allergens, and diabetes devices causing allergic contact dermatitis.Contact Dermatitis. 2025 Feb;92(2):87-112. doi: 10.1111/cod.14698. Epub 2024 Nov 26. Contact Dermatitis. 2025. PMID: 39600106 Free PMC article. Review.
-
Allergic contact dermatitis caused by glucose sensors and insulin pumps: A full review: Part 2. Case reports and case series, clinical features, patch test procedures, differentiation from irritant dermatitis, management of allergic patients and (proposed) legislation.Contact Dermatitis. 2025 Mar;92(3):164-175. doi: 10.1111/cod.14697. Epub 2024 Nov 26. Contact Dermatitis. 2025. PMID: 39600134 Free PMC article. Review.
Cited by
-
Incidence of allergic contact dermatitis in Finland 1998-2021: A nationwide registry-based study.Contact Dermatitis. 2025 Feb;92(2):113-119. doi: 10.1111/cod.14688. Epub 2024 Sep 10. Contact Dermatitis. 2025. PMID: 39253805 Free PMC article.
-
New Horizons in Skin Sensitization Assessment of Complex Mixtures: The Use of New Approach Methodologies Beyond Regulatory Approaches.Toxics. 2025 Aug 20;13(8):693. doi: 10.3390/toxics13080693. Toxics. 2025. PMID: 40863969 Free PMC article. Review.
-
The DERMIS Study: Methodologies, Results, and Implications for the Future.J Diabetes Sci Technol. 2024 Dec 5:19322968241298005. doi: 10.1177/19322968241298005. Online ahead of print. J Diabetes Sci Technol. 2024. PMID: 39633523 Free PMC article.
-
The Italian Trend of Contact Allergy to 2-Hydroxyethyl Methacrylate: Is the Current European Legislation Working?Contact Dermatitis. 2025 Sep;93(3):224-233. doi: 10.1111/cod.14800. Epub 2025 May 21. Contact Dermatitis. 2025. PMID: 40400120 Free PMC article.
-
Device-Related Skin Reactions Increase Emotional Burden in Youths With Type 1 Diabetes and Their Parents.J Diabetes Sci Technol. 2024 Nov;18(6):1293-1299. doi: 10.1177/19322968241253285. Epub 2024 May 28. J Diabetes Sci Technol. 2024. PMID: 38804535 Free PMC article.
References
-
- Al Shaikh A., Al Zahrani A.M., Qari Y.H., AbuAlnasr A.A., Alhawsawi W.K., Alshehri K.A., AlShaikh S.A. Quality of Life in Children with Diabetes Treated with Insulin Pump Compared with Multiple Daily Injections in Tertiary Care Center. Clin. Med. Insights Endocrinol. Diabetes. 2020;13:117955142095907. doi: 10.1177/1179551420959077. - DOI - PMC - PubMed
Publication types
MeSH terms
Substances
Grants and funding
LinkOut - more resources
Full Text Sources
Medical