Are Confirmatory Assays Reliable for HIV-1/HIV-2 Infection Differentiation? A Multicenter Study
- PMID: 37458587
- PMCID: PMC10446874
- DOI: 10.1128/jcm.00619-23
Are Confirmatory Assays Reliable for HIV-1/HIV-2 Infection Differentiation? A Multicenter Study
Abstract
Immunoblots remain the gold standard for HIV-1/HIV-2 infection confirmation. However, their ability to differentiate HIV-1 from HIV-2 infection on an antigenically diversified HIV-1 and HIV-2 panel remain uncommon. We performed a multicenter study on 116 serum samples accounting for most of the diversity of HIV-1 (9 different subtypes in group M, 17 circulating recombinant forms (CRFs), and 3 group O) and HIV-2 (groups A and B), evaluating seven confirmatory assays (six commercially available assays and one in-house assay) with genotyping as the reference. The assays were INNO-LIA HIV I/II score, HIV-2 blot 1.2, HIV blot 2.2, New Lav blot I and II, Geenius, and an in-house serotyping enzyme-linked immunosorbent assay (ELISA). Among the HIV-1 samples, INNO-LIA, HIV blot 2.2, New Lav blot I, Geenius, and serotyping had comparable high sensitivities, from 98% to 100%, whereas HIV-2 blot 1.2 and New Lav blot II had high rates of "undetermined" results (85% and 95%, respectively). HIV-2 blot 1.2 and New Lav blot II misclassified 7% and 5% of HIV-1 samples as HIV-2, respectively, and HIV-2 blot 1.2 had an 8% false-negative rate. Among the HIV-2 samples, INNO-LIA, New Lav blot II, HIV-2 blot 1.2, and serotyping had high sensitivities, from 96% to 100%. HIV blot 2.2 misclassified 17% of HIV-2 samples as HIV-1/HIV-2 dual infections. New Lav blot I misclassified 19% of HIV-2 samples as HIV-1 with a high (81%) undetermined rate, and Geenius misclassified 2% as HIV-1 and 7% as untypeable HIV positive. For HIV-1/HIV-2 dual infection, the results were less sensitive, with at most 87.5% for INNO-LIA and Geenius and 75% for HIV blot 2.2 and serotyping. Overall, confirmatory assays remain useful for most cases, with the exception of HIV-1/HIV-2 dual-infection suspicion.
Keywords: Geenius; HIV confirmation; HIV-1; HIV-2; INNO-LIA; Western blot; differentiation.
Conflict of interest statement
The authors declare no conflict of interest.
Figures

Similar articles
-
Staging of recent HIV-1 infection using Geenius rapid confirmatory assay compared to INNO-LIA, New Lav and Blot 2.2 assays.J Clin Virol. 2017 Oct;95:47-51. doi: 10.1016/j.jcv.2017.08.003. Epub 2017 Aug 18. J Clin Virol. 2017. PMID: 28843384
-
[Experience of the National HIV-AIDS Reference Center of Turkey, in the Transition to the New HIV Diagnostic Algorithm; Comparative Analysis of Line-Immunoassay Test and Bio-Rad Geenius™ HIV-1/2 Antibody Confirmatory Assay].Mikrobiyol Bul. 2021 Jan;55(1):17-29. doi: 10.5578/mb.20028. Mikrobiyol Bul. 2021. PMID: 33590978 Turkish.
-
Performance of Bio-Rad HIV-1/2 Confirmatory Assay in HIV-1, HIV-2 and HIV-1/2 dually reactive patients - comparison with INNO-LIA and immunocomb discriminatory assays.J Virol Methods. 2019 Jun;268:42-47. doi: 10.1016/j.jviromet.2019.03.005. Epub 2019 Mar 11. J Virol Methods. 2019. PMID: 30871983
-
Performance of the HIV Blot 2.2, INNO-LIA HIV I/II Score, and Geenius HIV 1/2 Confirmatory Assay for use in HIV confirmation.PLoS One. 2018 Jun 21;13(6):e0199502. doi: 10.1371/journal.pone.0199502. eCollection 2018. PLoS One. 2018. PMID: 29928045 Free PMC article.
-
Discriminatory capacity between HIV-1 and HIV-2 of the new rapid confirmation assay Geenius.J Virol Methods. 2014 Nov;208:11-5. doi: 10.1016/j.jviromet.2014.07.025. Epub 2014 Jul 27. J Virol Methods. 2014. PMID: 25075934
Cited by
-
Evaluation of the mindray CL900i CLIA HIV Ag/Ab combo assay for sensitive and specific HIV screening compared to established methods.Sci Rep. 2024 Nov 15;14(1):28177. doi: 10.1038/s41598-024-78271-z. Sci Rep. 2024. PMID: 39548153 Free PMC article.
-
Sensitivity and specificity of the new Bio-Rad HIV screening test, Access HIV combo V2.J Clin Microbiol. 2024 May 8;62(5):e0009524. doi: 10.1128/jcm.00095-24. Epub 2024 Mar 27. J Clin Microbiol. 2024. PMID: 38534108 Free PMC article.
-
Compact multiplex PCR device for HIV-1 and HIV-2 viral load determination from finger-prick whole blood in resource-limited settings.Biosens Bioelectron. 2025 Mar 1;271:116997. doi: 10.1016/j.bios.2024.116997. Epub 2024 Nov 26. Biosens Bioelectron. 2025. PMID: 39637742
References
-
- UNAIDS DATA. 2021. Joint United Nations Programme on HIV/AIDS, Geneva, Switzerland. https://www.unaids.org/sites/default/files/media_asset/JC3032_AIDS_Data_.... Accessed 7 September 2023.
-
- Rasmussen DN, Vieira N, Hønge BL, da Silva Té D, Jespersen S, Bjerregaard-Andersen M, Oliveira I, Furtado A, Gomes MA, Sodemann M, Wejse C, Unger HW. 2020. HIV-1 and HIV-2 prevalence, risk factors and birth outcomes among pregnant women in Bissau, Guinea-Bissau: a retrospective cross-sectional hospital study. Sci Rep 10:12174. doi:10.1038/s41598-020-68806-5. - DOI - PMC - PubMed
-
- Wang C, Hawes SE, Gaye A, Sow PS, Ndoye I, Manhart LE, Wald A, Critchlow CW, Kiviat NB. 2007. HIV prevalence, previous HIV testing, and condom use with clients and regular partners among Senegalese commercial sex workers. Sex Transm Infect 83:534–540. doi:10.1136/sti.2007.027151. - DOI - PMC - PubMed
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical