Slit-scan flow cytometry of mammalian chromosomes
- PMID: 374608
- DOI: 10.1177/27.1.374608
Slit-scan flow cytometry of mammalian chromosomes
Abstract
A flow cytometer has been constructed which measures total fluorescence and the distribution of fluorescence along isolated, stained mammalian chromosomes. In this device, chromosomes flow lengthwise at 4 m/sec through a 1-micrometer thick laser beam. The fluorescence from each chromosome is recorded at 10 nsec intervals; the sequence of recorded values represents the distribution of fluorescence along the chromosome and is stored in the memory of a waveform recorder. The total fluorescence of each chromosome is also measured and recorded. Preliminary studies show that doublets of 1.83 micrometers diameter microspheres flow with their long axes parallel to the direction of flow and that the two microspheres are resolved in the slit-scan profile. Ethidium bromide stained Muntjac and Chinese hamster chromosomes have also been slit-scanned. Centromeres were resolved in many of the Nos. 1 and 2 Chinese hamster chromosomes and the Nos. 1 and X + 3 Muntjac chromosomes.
Similar articles
-
Centromeric index measurement by slit-scan flow cytometry.Cytometry. 1983 Sep;4(2):109-16. doi: 10.1002/cyto.990040203. Cytometry. 1983. PMID: 6628135
-
Slit scan flow cytometry of isolated chromosomes following fluorescence hybridization: an approach of online screening for specific chromosomes and chromosome translocations.Z Naturforsch C J Biosci. 1991 May-Jun;46(5-6):433-41. doi: 10.1515/znc-1991-5-616. Z Naturforsch C J Biosci. 1991. PMID: 1910388
-
Two-parameter data acquisition system for rapid slit-scan analysis of mammalian chromosomes.Cytometry. 1987 Jan;8(1):83-90. doi: 10.1002/cyto.990080112. Cytometry. 1987. PMID: 3803098
-
Cytological indications of the complex subtelomeric structure.Cytogenet Genome Res. 2004;104(1-4):137-41. doi: 10.1159/000077478. Cytogenet Genome Res. 2004. PMID: 15162027 Review.
-
The use of fluorescence techniques for the recognition of mammalian chromosomes and chromosome regions.Int Rev Exp Pathol. 1972;11:1-72. Int Rev Exp Pathol. 1972. PMID: 4122097 Review. No abstract available.
Cited by
-
A reliable preparation of mon-dispersed chromosome suspensions for flow cytometry.Histochemistry. 1982;74(1):57-61. doi: 10.1007/BF00495052. Histochemistry. 1982. PMID: 7085351
-
High-resolution analysis of human peripheral lymphocyte chromosomes by flow cytometry.Proc Natl Acad Sci U S A. 1981 Dec;78(12):7727-31. doi: 10.1073/pnas.78.12.7727. Proc Natl Acad Sci U S A. 1981. PMID: 6950411 Free PMC article.
-
Characteristics of a simple, high-resolution flow cytometer based o a new flow configuration.Biophys J. 1979 Oct;28(1):33-44. doi: 10.1016/S0006-3495(79)85157-7. Biophys J. 1979. PMID: 400470 Free PMC article.
-
Real-time fluorescence and deformability cytometry.Nat Methods. 2018 May;15(5):355-358. doi: 10.1038/nmeth.4639. Epub 2018 Apr 2. Nat Methods. 2018. PMID: 29608556
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Other Literature Sources