A Clinically Viable Medial Olivocochlear Reflex Assay Using Transient-Evoked Otoacoustic Emissions
- PMID: 37475147
- DOI: 10.1097/AUD.0000000000001406
A Clinically Viable Medial Olivocochlear Reflex Assay Using Transient-Evoked Otoacoustic Emissions
Abstract
Objectives: The contralateral medial olivocochlear reflex (MOCR) strength may indicate various auditory conditions in humans, but a clinically viable assay and equipment are needed for quick, accurate, and reliable measurements. The first experiment compared an earlier version of the assay, which used a nonlinear-mode chirp stimulus, with a new assay using a linear-mode click stimulus, designed to give reliable MOCR measurements in most normal-hearing ears. The second experiment extended the improved assay on a purpose-built binaural hardware platform that used forward-pressure level (FPL) calibration for both the stimulus and the contralateral MOCR elicitor.
Design: Transient-evoked otoacoustic emission (TEOAE) tests were measured with and without a 60-dB SPL MOCR-evoking contralateral broadband noise. The normalized MOCR strength (MOCR%) was derived from the TEOAE responses for each trial pair using the complex pressure difference weighted by the TEOAE magnitude. Experiment 1 compared MOCR% within-subject and across-day using two TEOAE stimuli: nonlinear-mode chirps (50 dB SPL, bandpass 1-5 kHz, 14 ms window delayed by 2 ms) and linear-mode clicks (50 dB SPL, bandpass 0.5-2.5 kHz, 13 ms window delayed by 5 ms). TEOAE responses were analyzed in the 0.5 to 2.5 kHz band. Thirty adult participants with normal hearing (30 ears) completed the study. The TEOAE stimulus was calibrated in situ using spectral flattening, and the contralateral noise was calibrated in a coupler. Twelve TEOAE trial pairs were collected for each participant and condition. Experiment 2 used a purpose-built binaural system. The TEOAE stimuli were linear-mode clicks (50 dB SPL, bandpass 1-3 kHz, 13 ms window delayed by 5 ms), analyzed in the 1 to 3 kHz band over ~12 trial pairs. After a probe refit, an additional trial pair was collected for the two early-stopping signal-to-noise ratio criteria (15 and 20 dB). They were evaluated for single-trial reliability and test time. Nineteen adult participants with normal hearing (38 ears) completed the study. The TEOAE clicks and contralateral elicitor noise were calibrated in situ using FPL and delivered with automated timing.
Results: MOCR% for linear-mode clicks was distinguishable from measurement variability in 98% to 100% of participants' ears (both experiments), compared with only 73% for the nonlinear-mode chirp (experiment 1). MOCR detectability was assessed using the MOCR% across-subject/within-subject variance ratio. The ratio in experiment 1 for linear-mode clicks was higher (8.0) than for nonlinear-mode chirps (6.4). The ratio for linear-mode clicks (8.9) in experiment 2 was slightly higher than for the comparable linear-mode stimulus (8.0) in experiment 1. TEOAEs showed excellent reliability with high signal-to-noise ratios in both experiments, but reliability was higher for linear-mode clicks than nonlinear-mode chirps. MOCR reliability for the two stimuli was comparable. The FPL pressure response retest reliability derived from the SPL at the microphone was higher than the SPL retest reliability across 0.4 to 8 kHz. Stable results required 2 to 3 trial pairs for the linear-mode click (experiments 1 and 2) and three for the nonlinear-mode chirp (experiment 1), taking around 2 min on average.
Conclusions: The linear-mode click assay produced measurable, reliable, and stable TEOAE and MOCR results on both hardware platforms in around 2 min per ear. The stimulus design and response window ensured that any stimulus artifact in linear mode was unlikely to confound the results. The refined assay is ready to produce high-quality data quickly for clinical and field studies to develop population norms, recognize diagnostic patterns, and determine risk profiles.
Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved.
Conflict of interest statement
The authors have no conflicts of interest to disclose.
Similar articles
-
The Effect of Otoacoustic Emission Stimulus Level on the Strength and Detectability of the Medial Olivocochlear Reflex.Ear Hear. 2019 Nov/Dec;40(6):1391-1403. doi: 10.1097/AUD.0000000000000719. Ear Hear. 2019. PMID: 30896525
-
Otoacoustic-emission-based medial-olivocochlear reflex assays for humans.J Acoust Soc Am. 2014 Nov;136(5):2697-713. doi: 10.1121/1.4896745. J Acoust Soc Am. 2014. PMID: 25373970 Free PMC article.
-
Assessing Sensorineural Hearing Loss Using Various Transient-Evoked Otoacoustic Emission Stimulus Conditions.Ear Hear. 2017 Jul/Aug;38(4):507-520. doi: 10.1097/AUD.0000000000000425. Ear Hear. 2017. PMID: 28437273 Free PMC article.
-
Within- and Across-Subject Variability of Repeated Measurements of Medial Olivocochlear-Induced Changes in Transient-Evoked Otoacoustic Emissions.Ear Hear. 2016 Mar-Apr;37(2):e72-84. doi: 10.1097/AUD.0000000000000244. Ear Hear. 2016. PMID: 26583481
-
Does the Presence of Spontaneous Components Affect the Reliability of Contralateral Suppression of Evoked Otoacoustic Emissions?Ear Hear. 2021 July/Aug;42(4):990-1005. doi: 10.1097/AUD.0000000000000996. Ear Hear. 2021. PMID: 33480622
References
-
- Allen J. B., Robinson S. R., Lapsley Miller J. A., Jeng P. S., Levitt H. (2016). Middle-ear reflectance: concepts and clinical applications. In A. T. Cacace, E. de Kleine, A. G. Holt, P. van Dijk (Eds.), Scientific Foundations of Audiology: Perspectives from Physics, Biology, Modeling, and Medicine (pp. 1–40). Plural.
-
- ANSI. (2008). Maximum Permissible Ambient Noise Levels for Audiometric Test Rooms ANSI S3.1-1999(R-2008). (pp. 14). ANSI.
-
- ANSI/ASA. (2009). Methods for Manual Pure-Tone Threshold Audiometry (ANSI S3.21-2004 R2009). American National Standards Institute.
-
- Backus B. C., Guinan J. J. (2007). Measurement of the distribution of medial olivocochlear acoustic reflex strengths across normal-hearing individuals via otoacoustic emissions. J Assoc Res Otolaryngol, 8, 484–496.
-
- Bamber D. (1975). The area above the ordinal dominance graph and the area below the receiver operating characteristic graph. J Math Psychol, 12, 387–415.
REFERENCE NOTE
-
- Keppler H. (21 April 2021) personal communication.
-
- Bray P. (1989). Click evoked otoacoustic emissions and the development of a clinical otoacoustic hearing test instrument. Unpublished Ph.D. Thesis, University College and Middlesex School of Medicine, London.
-
- Williams E. A. (2000). Clinical applications of otoacoustic emissions in assessment of olivocochlear dysfunction. Unpublished PhD, UCL (University College London).