Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Aug 1;49(8):832-839.
doi: 10.1097/j.jcrs.0000000000001195.

Long-term trifocal toric intraocular lens outcomes in Asian eyes after cataract surgery

Affiliations

Long-term trifocal toric intraocular lens outcomes in Asian eyes after cataract surgery

Robert Edward T Ang. J Cataract Refract Surg. .

Abstract

Purpose: To determine the visual and refractive outcomes of trifocal toric intraocular lens (IOL) implantation in Asian eyes with cataract and astigmatism.

Setting: Asian Eye Institute, Makati City, Philippines.

Design: Prospective study.

Methods: 187 eyes were implanted with the FineVision POD FT IOL and followed for 2 years. The measurements included subjective refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), distance-corrected intermediate visual acuity (DCIVA), uncorrected near visual acuity (UNVA), distance-corrected near visual acuity (DCNVA), defocus curve, photopic and mesopic contrast sensitivity, and rotational stability.

Results: The mean spherical equivalent and cylinder values were, respectively, -0.07 ± 0.34 diopters (D) and -0.48 ± 0.31 D at the 2-year follow-up. At this same follow-up, 69.4% of patients had monocular CDVA and 79.3% had binocular UDVA ≤0.0 logMAR. For intermediate vision, monocular DCIVA reached 74.1%, while binocular UIVA was 86.2% ≤ 0.1 logMAR. Near vision showed 63% for monocular DCNVA and 70.7% for binocular UNVA ≤0.1 logMAR. The mean values at this follow-up were 0.02 ± 0.08, 0.08 ± 0.10, and 0.10 ± 0.12 logMAR for CDVA, DCIVA, and DCNVA, respectively. At the visual acuity threshold of ≤0.20 logMAR, the binocular defocus curve extended up to -3.75 D. Stable contrast sensitivity values were obtained at the different follow-ups. The mean IOL rotation was ≤2 degrees.

Conclusions: The FineVision POD FT IOL yielded good visual outcomes at far, near, and intermediate distances with accurate refractive outcomes and good rotational stability in Asian eyes.

PubMed Disclaimer

References

    1. Schallhorn JM, Pantanelli SM, Lin CC, Al-Mohtaseb ZN, Steigleman WA III, Santhiago MR, Olsen TW, Kim SJ, Waite AM, Rose-Nussbaumer JR. Multifocal and accommodating intraocular lenses for the treatment of presbyopia: a report by the American Academy of Ophthalmology. Ophthalmology 2021;128:1469–1482
    1. Berdahl JP, Hardten DR, Kramer BA, Potvin R. Effect of astigmatism on visual acuity after multifocal versus monofocal intraocular lens implantation. J Cataract Refract Surg 2018;44:1192–1197
    1. Day AC, Dhariwal M, Keith MS, Ender F, Perez Vives C, Miglio C, Zou L, Anderson DF. Distribution of preoperative and postoperative astigmatism in a large population of patients undergoing cataract surgery in the UK. Br J Ophthalmol 2019;103:993–1000
    1. Yoon JJ, Misra SL, McGhee CN, Patel DV. Demographics and ocular biometric characteristics of patients undergoing cataract surgery in Auckland, New Zealand. Clin Exp Ophthalmol 2016;44:106–113
    1. Tehrani M, Dick BH, Krummenauer F, Pfirrmann G, Boyle T, Stoffelns BM. Capsule measuring ring to predict capsular bag diameter and follow its course after foldable intraocular lens implantation. J Cataract Refract Surg 2003;29:2127–2134

LinkOut - more resources