Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jul 12;91(4):301-309.
doi: 10.3390/arm91040024.

Volatile Organic Compound Identification-Based Tuberculosis Screening among TB Suspects: A Diagnostic Accuracy Study

Affiliations

Volatile Organic Compound Identification-Based Tuberculosis Screening among TB Suspects: A Diagnostic Accuracy Study

Mayank Badola et al. Adv Respir Med. .

Abstract

Tuberculosis (TB) affects a third of the global population, and a large population of infected individuals still remain undiagnosed-making the visible burden only the tip of the iceberg. The detection of tuberculosis in close-proximity patients is one of the key priorities for attaining the Sustainable Development Goals (SDG) of TB elimination by 2030. With the current battery of screening tests failing to cover this need, the authors of this paper examined a simple and inexpensive point-of-care breath analyzer (TSI-3000(I)), which is based on detecting the volatile organic compounds that are emitted from infected cells and released in exhaled breath as a screening tool for the detection of TB. A single-center pilot study for assessing the diagnostic accuracy of the point-of-care Tuberculosis Breath Analyzer was conducted, and it was compared against the WHO-recommended TrueNat assay, which is a rapid molecular test and was also treated as the reference standard in this study. Of the 334 enrolled participants with TB signs/symptoms, 42.51% were TrueNat positive for Mycobacterium tuberculosis. The sensitivity of the Tuberculosis Breath Analyzer was found to be 95.7%, with a specificity of 91.3% and a ROC area of 0.935. The test kit showed considerable/significant high sensitivity and specificity as reliability indicators. The performance of the Tuberculosis Breath Analyzer tested was found to be comparable in efficiency to that of the TrueNat assay. A large cohort-based multicentric study is feasibly required to further validate and extrapolate the results of the pilot study.

Keywords: Mycobacterium tuberculosis; VOCs; breath testing; diagnostic accuracy study.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
Flow of Patients through the Study.
Figure 2
Figure 2
Spectroscopic display/topographic map.

References

    1. World Health Organization . Global Tuberculosis Report 2022. World Health Organization; Geneva, Switzerland: 2022.
    1. Thakur G., Thakur S., Thakur H. Status and challenges for tuberculosis control in India—Stakeholders’ perspective. Indian J. Tuberc. 2020;68:334–339. doi: 10.1016/j.ijtb.2020.10.001. - DOI - PMC - PubMed
    1. Central TB Division, Directorate General of Health Services Ministry of Health with Family Welfare, RNTCP, National Strategic Plan for Tuberculosis Elimination 2017–2025. [(accessed on 7 June 2023)]; Available online: https://tbcindia.gov.in/WriteReadData/NSP%20Draft%2020.02.2017%201.
    1. World Health Organization . World Health Organization; Geneva, Switzerland: 2021. [(accessed on 25 March 2022)]. Global Tuberculosis Report 2021: Supplementary Material. [Internet] Available online: https://www.who.int/teams/global-tuberculosis-programme/TB-reports/globa....
    1. Ministry of Health & Family Welfare—Government of India Revised National Tuberculosis Control Programme National Strategic Plan for Tuberculosis Elimination 2017–2025. [(accessed on 13 June 2023)];2021 India TB Report. Available online: https://tbcindia.gov.in/WriteReadData/National%20Strategic%20Plan%202017....

Substances