SPECT myocardial blood flow quantitation for the detection of angiographic stenoses with cardiac-dedicated CZT SPECT

Affiliations

SPECT myocardial blood flow quantitation for the detection of angiographic stenoses with cardiac-dedicated CZT SPECT

Jie Zhang et al. J Nucl Cardiol. 2023 Dec.

Abstract

Purpose: CZT SPECT with the enhanced imaging characteristic facilitates SPECT myocardial blood flow (MBF) quantitation moving toward a clinical utility to uncover myocardial ischemia. The purpose of this study was to investigate the diagnostic performance of stress MBF, myocardial flow reserve (MFR) and myocardial flow capacity (MFC) derived from CZT SPECT in the detection of coronary artery disease (CAD).

Methods: One-hundred and eighty patients underwent two-day rest/adenosine-stress scans for SPECT MBF quantitation. All dynamic SPECT images were reconstructed and corrected with necessary corrections. The one-tissue two-compartment kinetic model was utilized to fit kinetic parameters (K1, k2 and FBV) by numeric optimization and converted to MBF from K1. Rest MBF, stress MBF and MFR in left ventricle and coronary territories were calculated from flow polar maps. MFC was assessed by extents of moderately and severely abnormal flow statuses using an integrated flow diagram. Per-patient and per-vessel analyses were performed to determine cutoff values for the detection of angiographically obstructive and flow-limited CAD.

Results: Using the threshold of ≥ 50% stenosis, 149 patients (82.78%) were classified to have obstructive lesions in 355 vessels (65.74%). Using the threshold of ≥ 70% stenosis, 113 patients (62.78%) were classified to have flow-limited lesions in 282 vessels (52.22%). On per-patient analysis, the optimal cutoff values of stress MBF and MFR to detect ≥ 50% stenosis were (1.44 ml/min/g, 1.96) and (1.34 ml/min/g and 1.75) to detect ≥ 70% stenosis. The optimal cutoff values for severely and combined moderately severely abnormal MFC extents were (2.3-2.5%, 23.1%) and (7.5%, 29.4%), respectively. The overall sensitivity of MFC (0.84-0.86, 0.86-0.90) to detect ≥ 50% and ≥ 70% lesions surpassed those of stress MBF (0.78. 0.78) and MFR (0.80, 0.75) (all p < 0.05) with similar specificity (MFC = 0.84-0.90, 0.87-0.91; stress MBF = 0.87, 0.91; MFR = 0.84, 0.89) (all p≥ 0.05).

Conclusion: The non-invasive SPECT MBF quantitation using CZT SPECT is a reliable method to detect angiographically obstructive and flow-limited CAD. Myocardial flow capacity can outperform with higher diagnostic sensitivity than stress MBF or MFR alone.

Keywords: 99mTc-sestamibi; CZT SPECT; coronary artery disease; myocardial blood flow quantitation; myocardial flow capacity.

PubMed Disclaimer

References

    1. Nkoulou R, Fuchs TA, Pazhenkottil AP, Kuest SM, Ghadri JR, Stehli J, et al. Absolute myocardial blood flow and flow reserve assessed by gated SPECT with cadmium-zinc-telluride detectors using 99mTc-tetrofosmin: head-to-head comparison with 13N-ammonia PET. J Nucl Med 2016;57:1887‐92. - DOI - PubMed
    1. Giubbini R, Bertoli M, Durmo R, Bonacina M, Peli A, Faggiano I, et al. Comparison between N13-NH3 PET and 99mTc-Tetrofosmin-CZT SPECT in the evaluation of absolute myocardial blood flow and flow reserve. J Nucl Cardiol. 2019. https://doi.org/10.1007/s12350-019-01939-x . - DOI - PubMed
    1. Agostini D, Roule V, Nganoa C, et al. First validation of myocardial flow reserve assessed by dynamic 99mTc-sestamibi CZT-SPECT camera: head to head comparison with 15O-water PET and fractional flow reserve in patients with suspected coronary artery disease. The WATERDAY study. Eur J Nucl Med Mol Imaging. 2018;45(7):1079-1090.
    1. Ziadi MC, Dekemp RA, Williams K, Guo A, Renaud JM, Chow BJ, et al. Does quantification of myocardial flow reserve using rubidium-82 positron emission tomography facilitate detection of multivessel coronary artery disease? J Nucl Cardiol 2012;19:670‐80. - DOI - PubMed
    1. Murthy VL, Bateman TM, Beanlands RS, Berman DS, Borges-Neto S, Chareonthaitawee P, et al. Clinical quantification of myocardial blood flow using PET: joint position paper of the SNMMI Cardiovascular Council and the ASNC. J Nucl Cardiol 2018;25:269‐97. - DOI - PubMed

MeSH terms

LinkOut - more resources