Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
[Preprint]. 2023 Jul 11:2023.07.10.548464.
doi: 10.1101/2023.07.10.548464.

Genomic Surveillance of SARS-CoV-2 Using Long-Range PCR Primers

Affiliations

Genomic Surveillance of SARS-CoV-2 Using Long-Range PCR Primers

Sangam Kandel et al. bioRxiv. .

Update in

Abstract

Whole Genome Sequencing (WGS) of the SARS-CoV-2 virus is crucial in the surveillance of the COVID-19 pandemic. Several primer schemes have been developed to sequence the ~30,000 nucleotide SARS-CoV-2 genome that use a multiplex PCR approach to amplify cDNA copies of the viral genomic RNA. Midnight primers and ARTIC V4.1 primers are the most popular primer schemes that can amplify segments of SARS-CoV-2 (400 bp and 1200 bp, respectively) tiled across the viral RNA genome. Mutations within primer binding sites and primer-primer interactions can result in amplicon dropouts and coverage bias, yielding low-quality genomes with 'Ns' inserted in the missing amplicon regions, causing inaccurate lineage assignments, and making it challenging to monitor lineage-specific mutations in Variants of Concern (VoCs). This study uses seven long-range PCR primers with an amplicon size of ~4500 bp to tile across the complete SARS-CoV-2 genome. One of these regions includes the full-length S-gene by using a set of flanking primers. Using a small set of long-range primers to sequence SARS-CoV-2 genomes reduces the possibility of amplicon dropout and coverage bias.

PubMed Disclaimer

Conflict of interest statement

Competing Interest: None of the authors have competing financial interests or other conflicts of interest.

Figures

Figure 1:
Figure 1:
Comparison of ARTIC, Midnight, and Long-Range PCR primers. Long-range PCR primers used in this study include seven primer pairs to sequence the whole genome of SARS-CoV-2. The entire S-gene is sequenced by just one long-range primer. The horizontal dotted lines represent the viral genome segments amplified by each primer set.
Figure 2:
Figure 2:
IGV plot showing seven different amplicons mapped to the SARS-CoV-2 reference genome for four samples with low CT values. A) Samples with CT values 11.6, 15.1,14.3, and 18.3 from top to bottom, respectively. B) IGV plot for two samples (zoomed for the sample with CT values of 11.6 and 18.3 from top to bottom, respectively. The scale [0–36678] for the top and [0–48783], respectively, represents the range of the total number of the quality filtered reads that mapped to each amplicon region. The details of the reads mapped to different amplicon regions for four samples sequenced are summarized in Table 3 and Figure 3.
Figure 3:
Figure 3:
Histogram showing the number of reads mapped to each amplicon in the primer scheme. The ‘align_trim’ report file from the ARTIC pipeline was used in the ONTdeCIPHER tool. If the alignment length between the read and reference is <0.95% of the amplicon length, the read is discarded from the coverage plot. Amplicons are marked as dropped out if the total number of reads assigned to an amplicon is below 50. (X-axis: Seven amplicon regions tiled across the whole genome of SARS-CoV-2, amplifying seven regions along the viral genome. Y-axis: Total number of sequencing reads mapped to each amplicon region).
Figure 4:
Figure 4:
Bar chart showing the total number of samples passing quality. A 96-well plate with samples of different CT values was sequenced using Long-range and Midnight primers for comparison. Long-range primers and midnight primers work to accurately assign lineages and generate good-quality genomes for GenBank.
Figure 5:
Figure 5:
Bar chart showing samples sequenced with Midnight and Long-range primers with different CT values that passed quality. X-axis: CT value range, Y-axis Number of genomes passing quality.
Figure 6:
Figure 6:
Plot of genome coverage and CT values for the genomes that passed quality when sequenced using long-range primers. Long-range primers are effective in sequencing samples with CT values less than 20 to get at least 99 % genome coverage.
Figure 7:
Figure 7:
Diagrammatic representation of Oxford Nanopore Sequencing of SARS-CoV-2 using long-range PCR primers. (Figures made using BioRender.com)

References

    1. Aksamentov Ivan, Roemer Cornelius, Hodcroft Emma B., and Neher Richard A.. “Nextclade: Clade Assignment, Mutation Calling and Quality Control for Viral Genomes.” Journal of Open Source Software 6, no. 67 (November 30, 2021): 3773. 10.21105/joss.03773. - DOI
    1. Alkam Duah, Jenjaroenpun Piroon, Wongsurawat Thidathip, Udaondo Zulema, Patumcharoenpol Preecha, Robeson Michael, Haselow Dirk, et al. “Genomic Characterization of Mumps Viruses from a Large-Scale Mumps Outbreak in Arkansas, 2016.” Infection, Genetics, and Evolution 75 (November 1, 2019): 103965. 10.1016/j.meegid.2019.103965. - DOI - PMC - PubMed
    1. Arana Carlos, Liang Chaoying, Brock Matthew, Zhang Bo, Zhou Jinchun, Chen Li, Cantarel Brandi, Jeffrey SoRelle Lora V. Hooper, and Raj Prithvi. “A Short plus Long-Amplicon Based Sequencing Approach Improves Genomic Coverage and Variant Detection in the SARS-CoV-2 Genome.” PLOS ONE 17, no. 1 (January 13, 2022): e0261014. 10.1371/journal.pone.0261014. - DOI - PMC - PubMed
    1. Bakhshandeh Behnaz, Jahanafrooz Zohreh, Abbasi Ardeshir, Matin Babaee Goli Mahya Sadeghi, Mohammad Sadeq Mottaqi, and Maryam Zamani. “Mutations in SARS-CoV-2; Consequences in Structure, Function, and Pathogenicity of the Virus.” Microbial Pathogenesis 154 (May 1, 2021): 104831. 10.1016/j.micpath.2021.104831. - DOI - PMC - PubMed
    1. Bei Yanxia, Pinet Kaylinnette, Vrtis Kyle B., Borgaro Janine G., Sun Luo, Campbell Matthew, Apone Lynne, Langhorst Bradley W., and Nichols Nicole M.. “Overcoming Variant Mutation-Related Impacts on Viral Sequencing and Detection Methodologies.” Frontiers in Medicine 9 (2022). 10.3389/fmed.2022.989913. - DOI - PMC - PubMed

Publication types