Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2024 Feb;63(2):214-221.
doi: 10.1002/uog.27441.

Angiogenic imbalance in maternal and cord blood is associated with neonatal birth weight and head circumference in pregnancies with major fetal congenital heart defect

Affiliations
Free article
Multicenter Study

Angiogenic imbalance in maternal and cord blood is associated with neonatal birth weight and head circumference in pregnancies with major fetal congenital heart defect

O Sánchez et al. Ultrasound Obstet Gynecol. 2024 Feb.
Free article

Abstract

Objectives: To ascertain whether abnormalities in neonatal head circumference and/or body weight are associated with levels of angiogenic/antiangiogenic factors in the maternal and cord blood of pregnancies with a congenital heart defect (CHD) and to assess whether the specific type of CHD influences this association.

Methods: This was a multicenter case-control study of women carrying a fetus with major CHD. Recruitment was carried out between June 2010 and July 2018 at four tertiary care hospitals in Spain. Maternal venous blood was drawn at study inclusion and at delivery. Cord blood samples were obtained at birth when possible. Placental growth factor (PlGF), soluble fms-like tyrosine kinase-1 (sFlt-1) and soluble endoglin (sEng) were measured in maternal and cord blood. Biomarker concentrations in the maternal blood were expressed as multiples of the median (MoM).

Results: PlGF, sFlt-1 and sEng levels were measured in the maternal blood in 237 cases with CHD and 260 healthy controls, and in the cord blood in 150 cases and 56 controls. Compared with controls, median PlGF MoM in maternal blood was significantly lower in the CHD group (0.959 vs 1.022; P < 0.0001), while median sFlt-1/PlGF ratio MoM was significantly higher (1.032 vs 0.974; P = 0.0085) and no difference was observed in sEng MoM (0.981 vs 1.011; P = 0.4673). Levels of sFlt-1 and sEng were significantly higher in cord blood obtained from fetuses with CHD compared to controls (mean ± standard error of the mean, 447 ± 51 vs 264 ± 20 pg/mL; P = 0.0470 and 8.30 ± 0.92 vs 5.69 ± 0.34 ng/mL; P = 0.0430, respectively). Concentrations of sFlt-1 and the sFlt-1/PlGF ratio in the maternal blood at study inclusion were associated negatively with birth weight and head circumference in the CHD group. The type of CHD anomaly (valvular, conotruncal or left ventricular outflow tract obstruction) did not appear to alter these findings.

Conclusions: Pregnancies with fetal CHD have an antiangiogenic profile in maternal and cord blood. This imbalance is adversely associated with neonatal head circumference and birth weight. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.

Keywords: PlGF; congenital heart defect; cord blood; maternal blood; neonatal cephalic biometry; placental growth factor; sFlt-1; soluble fms-like tyrosine kinase-1.

PubMed Disclaimer

References

REFERENCES

    1. Donofrio MT, Moon-Grady AJ, Hornberger LK, Copel JA, Sklansky MS, Abuhamad A, Cuneo BF, Huhta JC, Jonas RA, Krishnan A, Lacey S, Lee W, Michelfelder EC Sr, Rempel GR, Silverman NH, Spray TL, Strasburger JF, Tworetzky W, Rychik J; American Heart Association Adults With Congenital Heart Disease Joint Committee of the Council on Cardiovascular Disease in the Young and Council on Clinical Cardiology, Council on Cardiovascular Surgery and Anesthesia, and Council on Cardiovascular and Stroke Nursing. Diagnosis and treatment of fetal cardiac disease: a scientific statement from the American Heart Association. Circulation 2014; 129: 2183-2242.
    1. Bakiler AR, Ozer EA, Kanik A, Kanit H, Aktas FN. Accuracy of prenatal diagnosis of congenital heart disease with fetal echocardiography. Fetal Diagn Ther 2007; 22: 241-244.
    1. Donofrio MT, Massaro AN. Impact of congenital heart disease on brain development and neurodevelopmental outcome. Int J Pediatr 2010; 2010: 359390.
    1. Khalil A, Suff N, Thilaganathan B, Hurrell A, Cooper D, Carvalho JS. Brain abnormalities and neurodevelopmental delay in congenital heart disease: systematic review and meta-analysis. Ultrasound Obstet Gynecol 2014; 43: 14-24.
    1. Masoller N, Martinez JM, Gomez O, Bennasar M, Crispi F, Sanz-Cortes M, Egana-Ugrinovic G, Bartrons J, Puerto B, Gratacos E. Evidence of second-trimester changes in head biometry and brain perfusion in fetuses with congenital heart disease. Ultrasound Obstet Gynecol 2014; 44: 182-187.

Publication types

LinkOut - more resources