Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Sep;40(9):892-902.
doi: 10.1111/echo.15664. Epub 2023 Jul 31.

Improving accuracy in diagnosing aortic stenosis severity: An in-depth analysis of echocardiographic measurement error through literature review and simulation study

Affiliations

Improving accuracy in diagnosing aortic stenosis severity: An in-depth analysis of echocardiographic measurement error through literature review and simulation study

Bart J J Velders et al. Echocardiography. 2023 Sep.

Abstract

Aims: The present guidelines advise replacing the aortic valve for individuals with severe aortic stenosis (AS) based on various echocardiographic parameters. Accurate measurements are essential to avoid misclassification and unnecessary interventions. The objective of this study was to evaluate the influence of measurement error on the echocardiographic evaluation of the severity of AS.

Methods and results: A systematic review was performed to examine whether measurement errors are reported in studies focusing on the prognostic value of peak aortic jet velocity (Vmax ), mean pressure gradient (MPG), and effective orifice area (EOA) in asymptomatic patients with AS. Out of the 37 studies reviewed, 17 (46%) acknowledged the existence of measurement errors, but none of them utilized methods to address them. Secondly, the magnitude of potential errors was collected from available literature for use in clinical simulations. Interobserver variability ranged between 0.9% and 8.3% for Vmax and MPG but was higher for EOA (range 7.7%-12.7%), indicating lower reliability. Assuming a circular left ventricular outflow tract area led to a median underestimation of EOA by 23% compared to planimetry by other modalities. A clinical simulation resulted in the reclassification of 42% of patients, shifting them from a diagnosis of severe AS to moderate AS.

Conclusions: Measurement errors are underreported in studies on echocardiographic assessment of AS severity. These errors can lead to misclassification and misdiagnosis. Clinicians and scientists should be aware of the implications for accurate clinical decision-making and assuring research validity.

Keywords: aortic stenosis; echocardiography; misclassification; random/systematic measurement error.

PubMed Disclaimer

References

REFERENCES

    1. Généreux P, Stone GW, O'Gara PT, et al. Natural history, diagnostic approaches, and therapeutic strategies for patients with asymptomatic severe aortic stenosis. J Am Coll Cardiol. 2016;67(19):2263-2288.
    1. Baumgartner H, Hung J, Bermejo J, et al. Recommendations on the echocardiographic assessment of aortic valve stenosis: a focused update from the European association of cardiovascular imaging and the American society of echocardiography. J Am Soc Echocardiogr. 2017;30(4):372-392.
    1. Gahl B, Çelik M, Head SJ, et al. Natural history of asymptomatic severe aortic stenosis and the association of early intervention with outcomes: a systematic review and meta-analysis. JAMA Cardiol. 2020;5(10):1102-1112.
    1. Lancellotti P, Magne J, Dulgheru R, et al. Outcomes of patients with asymptomatic aortic stenosis followed up in heart valve clinics. JAMA Cardiol. 2018;3(11):1060-1068.
    1. Rosenhek R, Binder T, Porenta G, et al. Predictors of outcome in severe, asymptomatic aortic stenosis. N Engl J Med. 2000;343(9):611-617.

Publication types

LinkOut - more resources