Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Nov 1;47(8):737-745.
doi: 10.1093/jat/bkad049.

The impact of vaping ethanol-containing electronic cigarette liquids on roadside impairment investigations

Affiliations

The impact of vaping ethanol-containing electronic cigarette liquids on roadside impairment investigations

Alaina K Holt et al. J Anal Toxicol. .

Abstract

Legal professionals and others have suggested that vaping electronic cigarettes (e-cigs) prior to or during ethanol breath testing may produce false positives. Preliminary breath tests (PBTs) and evidentiary breath tests (EBTs) measure ethanol in exhaled breath and standardized field sobriety tests (SFSTs) are used to assess impairment. Ethanol has been identified in e-cig liquids (e-liquids). Presented are a series of experiments designed to determine the mechanics of vaping ethanol using an e-cig and the effects of vaping ethanol on the SFSTs and breath tests used by law enforcement officers (LEO). Twelve participants (five females, age: 21-32 and seven males, age: 21-55), vaped either one or ten puffs of an e-liquid (0% or 20% ethanol). LEOs assessed impairment using SFSTs (12 and 42 min), PBTs (<1, 27, 32, 37 and 57 min) and EBTs (2, 29, 34, 39 and 59 min) post-vaping. A self-assessment test was administered post-vaping (22 and 52 min). Baseline responses for all measures were collected prior to vaping. Results demonstrated that ethanol in the e-liquids was aerosolized by e-cigs and produced particles that could reach the deep lung tissue based on mean-mass diameter. Ethanol was detected by PBT <3 min after participants vaped one (0.007-0.030 g/210 L) or ten puffs (013-0.074 g/210 L) of a 20% ethanol e-liquid. Ethanol was not detected by PBT at any subsequent time point. Ethanol was not detected by the EBT under any condition. Impairment was not indicated by the SFST. Some subjective effects were reported, but few statistically significant differences between conditions were indicated. A wait period prior to ethanol breath testing is not always mandated, depending on jurisdiction, or observed in all applications, such as workplace testing. The results demonstrate that a wait period must be employed to prevent vaping-related false-positive breath ethanol results.

PubMed Disclaimer

Figures

Figure 1.
Figure 1.
Visual diagram of the clinical design, including the vaping regimen and approximate timeline for vaping and collecting measures.
Figure 2.
Figure 2.
(A) Average ethanol concentration (µg) per puff for e-liquids containing 5%, 10%, 15% or 20% ethanol. (B) Average ethanol concentration (µg) per puff deposited on MOUDI stages using e-liquids containing 5%, 10%, 15%, or 20% ethanol.
Figure 3.
Figure 3.
PBT results by time point (A) and time point 2 session condition (B); time point 2 PBT results compared to total puff volume for 20% ethanol conditions (C).

References

    1. WARNING!! DUI from Mentholated e-juice E-Cigarette Forum. https://www.e-cigarette-forum.com/threads/warning-dui-from-mentholated-e... (accessed Oct 4, 2022).
    1. Law Offices of Charles L. Waechter . (2018) Vaping Alcohol Can Get You a DUI. https://www.waechterlawfirm.com/blog/2018/05/vaping-alcohol-can-get-you-... (accessed Oct 4, 2022).
    1. Burns M., Anderson E.W. (1995) A Colorado Validation Study of the Standardized Field Sobriety Test (SFST) Battery. Colorado Department of Transportation.
    1. Burns M., Dioquino T. (1997) A Florida Validation Study of the Standardized Field Sobriety Test (S.F.S.T.) Battery: (730472011-001). http://doi.apa.org/get-pe-doi.cfm?doi=10.1037/e730472011-001 (accessed Aug 9, 2022).
    1. Stuster J., Burns M. (1998) Validation of the Standardized Field Sobriety Test Battery at BACs Below 0.10 Percent. https://www.ojp.gov/pdffiles1/Photocopy/197439NCJRS.pdf (accessed Aug 9, 2022).