Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2024 Dec;61(12):1957-1968.
doi: 10.1177/10556656231190525. Epub 2023 Aug 1.

Evaluating Prenatal Diagnostic Imaging for Micrognathia: A Systematic Review and Meta-Analysis

Affiliations
Meta-Analysis

Evaluating Prenatal Diagnostic Imaging for Micrognathia: A Systematic Review and Meta-Analysis

Caroline M Fields et al. Cleft Palate Craniofac J. 2024 Dec.

Abstract

Objective: Studies evaluating the ability to diagnose and accurately predict the severity of micrognathia prenatally have yielded inconsistent results. This review aimed to evaluate reliability of prenatal diagnostic imaging in the diagnosis and characterization of micrognathia.

Design: Systematic review and meta-analysis.

Setting: Studies with a prenatal diagnosis of micrognathia via ultrasound with a confirmatory postnatal examination were included. Prenatal severity was defined with and without mandibular measurements. Extent of airway obstruction at birth was defined by level of intervention required. Meta-analyses of proportions and relative risk were performed.

Patients: A total of 16 studies with 2753 neonates were included.

Main outcome measures: Primary outcome was the efficacy of characterizing the degree of micrognathia on prenatal imaging as it relates to respiratory obstruction at birth. Secondary outcome was the accuracy of prenatal diagnosis with the utilization of mandibular measurements versus without.

Results: Performing meta-analysis of proportions, the proportion of missed prenatal diagnoses of micrognathia made without mandibular measurements was 11.62% (95%CI 2.58-25.94). Utilizing mandibular measurements, the proportion of cases missed were statistically lower (0.20% [95%CI 0.00-0.70]). Patients determined to have severe micrognathia by prenatal imaging did not have a statistically significant increase in risk for more severe respiratory obstruction at birth (RR 3.13 [95%CI 0.59-16.55], P = .180).

Conclusion: The proportion micrognathia cases missed when prenatal diagnosis was made without mandibular measurements was over 1 in 10, with mandibular measures improving accuracy. This study highlights the need for a uniform objective criterion to improve prenatal diagnosis and planning for postnatal care.

Keywords: micrognathia; prenatal diagnosis; ultrasound.

PubMed Disclaimer

Conflict of interest statement

Declaration of Conflicting InterestsThe author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Similar articles

Cited by

  • The Ex-utero intrapartum treatment procedure: a narrative review.
    Gaffuri M, Raffaeli G, Bullejos Garcia EE, Perugino G, Cassardo O, Persico N, Colnaghi M, Garrido F, Villamor E, Cetin I, Fumagalli M, Pignataro L, Cavallaro G. Gaffuri M, et al. Front Pediatr. 2025 Jul 17;13:1601963. doi: 10.3389/fped.2025.1601963. eCollection 2025. Front Pediatr. 2025. PMID: 40746351 Free PMC article. Review.

LinkOut - more resources