Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Meta-Analysis
. 2023 Sep:90:102025.
doi: 10.1016/j.arr.2023.102025. Epub 2023 Jul 30.

Delirium assessment tools among hospitalized older adults: A systematic review and metaanalysis of diagnostic accuracy

Affiliations
Meta-Analysis

Delirium assessment tools among hospitalized older adults: A systematic review and metaanalysis of diagnostic accuracy

Chia-Jou Lin et al. Ageing Res Rev. 2023 Sep.

Abstract

Delirium is a common neuropsychiatric syndrome that is often overlooked in clinical settings. The most accurate instrument for screening delirium has not been established. This study aimed to compare the diagnostic accuracy of the 4 'A's Test (4AT), Nursing Delirium Screening Scale (Nu-DESC), and Confusion Assessment Method (CAM) in detecting delirium among older adults in clinical settings. These assessment tools feature concise item sets and straightforward administration procedures. Five electronic databases were systematically searched from their inception to September 7, 2022. Studies evaluating the sensitivity and specificity of the 4AT, Nu-DESC, and CAM against the Diagnostic and Statistical Manual of Mental Disorders or International Classification of Diseases as the reference standard were included. Bivariate random effects model was used to summarize the sensitivity and specificity results. A total of 38 studies involving 7378 patients were included. The 4AT, Nu-DESC, and CAM had comparable sensitivity in detecting delirium (0.76, 0.78, and 0.80, respectively). However, the specificity of the CAM was higher than that of the 4AT (0.98 vs 0.89, P = .01) and Nu-DESC 0.99 vs 0.90, P = .003). Diagnostic accuracy was moderated by the percentage of women, acute care setting, sample size, and assessors. The three tools exhibit comparable sensitivity, and the CAM has the highest specificity. Based on the feasibility of the tools, nurses and clinical staffs could employ the Nu-DESC and the 4AT on screening out positive delirium cases and integrate these tools into daily practice. Further investigations are warranted to verify our findings.

Keywords: Confusion Assessment Method; Delirium; Nursing Delirium Screening Scale; Older adults; The 4 ‘A’s Test.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare no potential conflicts of interest regarding the authorship or publication of this article.

Publication types

LinkOut - more resources