Trial of a Novel Radiation Shielding Device to Protect Staff in the Cardiac Catheter Laboratory

Affiliations
Randomized Controlled Trial

Trial of a Novel Radiation Shielding Device to Protect Staff in the Cardiac Catheter Laboratory

James A Crowhurst et al. Am J Cardiol. .

Abstract

Continuous exposure to low-level scattered radiation to staff performing cardiac angiography and intervention is of concern. A novel shielding solution (NSS) (Rampart IC M1128) has the potential to provide greater shielding for staff present at the table-side. This study aimed to investigate the effectiveness of the NSS compared with a traditional shielding solution (TSS) in a randomized controlled trial that enrolled 100 patients who underwent cardiac angiography and/or intervention which were randomized to the NSS or TSS. Baseline patient characteristics and radiation dose data were collected. Staff who were scrubbed at the table-side wore 5 real-time dosimeters on the head, collar, waist, ankle, and under the apron. The median primary operator radiation dose was significantly lower (p <0.001) for all dosimeter locations with the NSS when compared with the TSS, being reduced by 86%, 80.0%, 100%, and 50.0% for the head, collar, waist, and leg respectively. Median under-apron dose was 0.0 µSv for both NSS and TSS. Median second operator dose was reduced by 100%, 100%, and 100% for the head, collar, and waist respectively (p <0.001). Median NSS and TSS dose at the ankle and under apron was 0.0 µSv. Median scrub nurse dose was reduced by 50% and 100% for the head and collar respectively (p <0.001). Median NSS and TSS dose at the waist, ankle, and under apron was 0.0 µSv. In conclusion, the NSS tested in this study demonstrates a significant decrease in radiation dose to operators and scrub nurses when compared with traditional radiation protection measures.

Keywords: coronary angiography; radiation protection; shielding.