. 2023 Sep:166:111020.
doi: 10.1016/j.ejrad.2023.111020. Epub 2023 Jul 31.

Efficacy of modified time of flight magnetic resonance venography in diagnosis of iliac vein compression syndrome

Affiliations

Efficacy of modified time of flight magnetic resonance venography in diagnosis of iliac vein compression syndrome

Gang Peng et al. Eur J Radiol. 2023 Sep.

Abstract

Objective: We investigated the diagnostic efficacy of modified time of flight magnetic resonance venography (mTOF-MRV) for iliac vein compression syndrome diagnosis by optimizing the scanning parameters and improving image quality.

Methods: A retrospective study was conducted on 69 patients who underwent routine time of flight magnetic resonance venography (TOF-MRV) and 85 patients who received mTOF-MRV. Assessment of image quality of the two methods was performed by two radiologists using a four-point method. The sensitivity, specificity, positive and negative predictive values of TOF-MRV and mTOF-MRV in the diagnosis of significant iliac vein compression (stenosis >50%) were analyzed by calculating the iliac vein stenosis rates of the two methods and using digital subtraction angiography (DSA) as the gold standard.

Results: Inter-observer assessment of objective data measurement revealed excellent agreement {ICC [95% confidence interval (CI)]: 0.972 (0.953 to 0.983) for TOF-MRV and 0.979 (0.965 to 0.988) for m-TOF MRV, 0.976 (0.960 to 0.986) for DSA}. The mean error of stenosis rate of mTOF-MRV was markedly smaller than that of TOF-MRV (p < 0.05). Sensitivity, specificity, positive and negative predictive values of TOF-MRV in the diagnosis of significant stenosis were 100%, 95%, 67% and 100%, respectively. The sensitivity, specificity, positive and negative predictive values of mTOF-MRV were 100%. The mean image score for the mTOF-MRV was 3.63 ± 0.59, which was significantly higher compared with that of TOF-MRV (2.19 ± 0.42).

Conclusion: mTOF-MRV has better image quality and can accurately diagnose venous stenosis. Therefore, it can be used for the detection of iliac vein compression syndrome and further assessment after endovascular interventions.

Keywords: Iliac vein compression syndrome; Modified; Non-contrast-enhanced magnetic resonance venography; Time-of-flight.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

MeSH terms

LinkOut - more resources