[Detectability of glaucomatous visual field defects with the Octopus automatic perimeter. A comparison between program G-1 and programs 31 and 32 and their combinations]
- PMID: 3754292
- DOI: 10.1055/s-2008-1050569
[Detectability of glaucomatous visual field defects with the Octopus automatic perimeter. A comparison between program G-1 and programs 31 and 32 and their combinations]
Abstract
Twenty-three patients between 31 and 76 years of age suffering from either hypertension or glaucoma underwent automatic perimetry with Octopus programs 31 or 32, followed by program G-1. This was done to compare the information content of the latter, new program with that of the former two, long-used in different combinations. Only one eye of any one patient was considered in this study. Using an evaluation program, the G-1 program calculates the so-called "field indices" which help to interpret the results. These field indices are the mean differential light sensitivity threshold (mDLS), the mean defect (MD), the loss variance (LV), and the corrected loss variance (corrected for short-term fluctuations (CLV)). In order to compare programs 31, 32, and their combination 31 + 32, with the field indices of program G-1, the mean DLS was taken from the Delta evaluation program, while the mean defect, the loss variance, and the corrected loss variance were calculated on the basis of programs 31, 32, and the combination of them. The mDLS and mean defect determined with program G-1 were significantly different from those found with programs 31, 32, and the combination of them. On the one hand, this was due to the difference in test patterns, that of G-1 being more centrally weighted; on the other hand, this is indicative of the precision and discrimination capability of Octopus measurements. Calculation of loss variance and corrected loss variance reveals no significant difference between the examination methods as regards these field indices, that is, between G-1 and 31, 32, or 31 + 32.(ABSTRACT TRUNCATED AT 250 WORDS)
Similar articles
-
[Quantification and progression of the visual field defect in glaucoma without hypertension, glaucoma simplex and pigmentary glaucoma. A clinical study with the Delta Program of the 201 Octopus perimeter].Klin Monbl Augenheilkd. 1987 Sep;191(3):184-98. doi: 10.1055/s-2008-1050492. Klin Monbl Augenheilkd. 1987. PMID: 3682683 German.
-
[Measuring the optic papilla with planimetry and the optic nerve head analyzer in glaucoma and suspected glaucoma. II. Correlations of the results of both methods with changes in the visual field, studied with the Octopus automatic perimeter].Klin Monbl Augenheilkd. 1990 Mar;196(3):132-42. doi: 10.1055/s-2008-1046143. Klin Monbl Augenheilkd. 1990. PMID: 2342313 German.
-
[Optimizing the distribution and test locations in statistical perimetry. Preliminary results].Klin Monbl Augenheilkd. 1997 May;210(5):302-4. doi: 10.1055/s-2008-1035058. Klin Monbl Augenheilkd. 1997. PMID: 9324538 German.
-
Computer-assisted interpretation of visual fields in glaucoma.Acta Ophthalmol Suppl (1985). 1992;(206):1-47. Acta Ophthalmol Suppl (1985). 1992. PMID: 1467748 Review.
-
Simulation in perimetry -- program Perisim 2000.Ophthalmologica. 2005 May-Jun;219(3):123-8. doi: 10.1159/000085243. Ophthalmologica. 2005. PMID: 15947496 Review.
Cited by
-
Neuroretinal rim area and visual field in glaucoma.Graefes Arch Clin Exp Ophthalmol. 1988;226(5):431-4. doi: 10.1007/BF02170003. Graefes Arch Clin Exp Ophthalmol. 1988. PMID: 3192093
-
Spectrometric investigations in ocular hypertension and early stages of primary open angle glaucoma and of low tension glaucoma--multisubstance analysis.Int Ophthalmol. 1992 Sep;16(4-5):251-7. doi: 10.1007/BF00917971. Int Ophthalmol. 1992. PMID: 1428553
-
The influence of stimulus parameters on the visual field indices by automated projection perimetry.Graefes Arch Clin Exp Ophthalmol. 1993 Jun;231(6):337-43. doi: 10.1007/BF00919030. Graefes Arch Clin Exp Ophthalmol. 1993. PMID: 8339949
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical