. 2023 Aug 21;6(8):3266-3277.
doi: 10.1021/acsabm.3c00362. Epub 2023 Aug 9.

N-Nitrosation Based Fluorescence Turn-On Nitric Oxide Probe: Kinetic and Cell Imaging Studies

Affiliations

N-Nitrosation Based Fluorescence Turn-On Nitric Oxide Probe: Kinetic and Cell Imaging Studies

Ananya Dutta et al. ACS Appl Bio Mater. .

Abstract

Nitric oxide (NO) is a ubiquitous messenger molecule playing a key role in various physiological and pathological processes. However, producing a selective turn-on fluorescence response to NO is a challenging task due to (a) the very short half-life of NO (typically in the range of 0.1-10 s) in the biological milieu and (b) false positive responses to reactive carbonyl species (RCS) (e.g., dehydroascorbic acid and methylglyoxal etc.) and some other reactive oxygen/nitrogen species (ROS/RNS), especially with o-phenylenediamine (OPD) based fluorosensors. To avoid these limitations, NO sensors should be designed in such a way that they react spontaneously with NO to give turn-on response within the time frame of t1/2 (typically in the range of 0.1-10 s) of NO and λem in the visible wavelength along with good cell permeability to achieve biocompatibility. With these views in mind, a N-nitrosation based fluorescent sensor, NDAQ, has been developed that is highly selective to NO with ∼27-fold fluorescence enhancement at λem = 542 nm with high sensitivity (LOD = 7 ± 0.4 nM) and shorter response time, eliminating the interference of other reactive species (RCS/ROS/RNS). Furthermore, all the photophysical studies with NDAQ have been performed in 98% aqueous medium at physiological pH, indicating its good stability under physiological conditions. The kinetic assay illustrates the second-order dependency with respect to NO concentration and first-order dependency with respect to NDAQ concentration. The biological studies reveal the successful application of the probe to track both endogenous and exogenous NO in living organisms.

Keywords: DFT calculation; Endogenous detection; Exogenous detection; Kinetic studies; N-nitrosation mechanism; NO sensor.