Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2023 Sep;51(11):2850-2857.
doi: 10.1177/03635465231188975. Epub 2023 Aug 16.

Development and Validation of a Short-Form Version of the Western Ontario Shoulder Instability Scale (Short-WOSI)

Affiliations
Multicenter Study

Development and Validation of a Short-Form Version of the Western Ontario Shoulder Instability Scale (Short-WOSI)

Cale A Jacobs et al. Am J Sports Med. 2023 Sep.

Abstract

Background: Patient-reported outcome measures (PROMs) have transitioned from primarily being used as research instruments to becoming increasingly used in the clinical setting to assess recovery and inform shared decision-making. However, there is a need to develop validated short-form PROM instruments to decrease patient burden and ease incorporation into clinical practice.

Purpose: To assess the validity and responsiveness of a shortened version of the Western Ontario Shoulder Instability Index (Short-WOSI) when compared with the full WOSI and other shoulder-related PROM instruments.

Study design: Cohort study (diagnosis); Level of evidence, 2.

Methods: This study was a secondary analysis of data collected as part of an institutional review board-approved, multicenter cohort of 1160 patients undergoing surgical stabilization for shoulder instability. The following PROMs were captured preoperatively and 2 years after surgery: WOSI, American Shoulder and Elbow Surgeons (ASES) score, the Single Assessment Numeric Evaluation (SANE), and 36-Item Health Survey (RAND-36). The cohort was split into 2 data sets: a training set to be used in the development of the Short-WOSI (n = 580) and a test set to be used to assess the validity and responsiveness of the Short-WOSI relative to the full WOSI, ASES, SANE, and RAND-36.

Results: The Short-WOSI demonstrated excellent internal consistency before surgery (Cronbach α = .83) and excellent internal consistency at the 2-year follow-up (Cronbach α = .93). The baseline, 2-year, and pre- to postoperative changes in Short-WOSI and WOSI were closely correlated (r > 0.90), with both demonstrating large effect sizes (Short-WOSI = 1.92, WOSI = 1.81). Neither the Short-WOSI nor the WOSI correlated well with the other PROM instruments before (r = 0.21-0.33) or after (r = 0.25-0.38) surgery. The Short-WOSI, WOSI, and SANE scores were more responsive than ASES and RAND-36 scores.

Conclusion: The 7-item Short-WOSI demonstrated excellent internal consistency and a lack of floor or ceiling effects. The Short-WOSI demonstrated excellent cross-sectional and longitudinal construct validity and was similarly responsive over time as the full WOSI. Neither the Short-WOSI nor WOSI correlated with more general shoulder PROMs, underscoring the advantage of using instability-specific instruments for this population.

Keywords: dislocation; instability; patient-reported outcome; responsiveness; shoulder; validity.

PubMed Disclaimer

Publication types

LinkOut - more resources