Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2023 Oct;131(10):543-551.
doi: 10.1111/apm.13346. Epub 2023 Aug 17.

Performance of automated antimicrobial susceptibility testing for the detection of antimicrobial resistance in gram-negative bacteria: a NordicAST study

Collaborators, Affiliations
Multicenter Study

Performance of automated antimicrobial susceptibility testing for the detection of antimicrobial resistance in gram-negative bacteria: a NordicAST study

Truls M Leegaard et al. APMIS. 2023 Oct.

Abstract

Automated testing of antimicrobial susceptibility is common in clinical microbiology laboratories but their ability to detect low-level resistance has been questioned. This Nordic multicentre study aimed to evaluate the performance of commercially available automated AST systems. A phenotypically well-characterised collection of gram-negative bacilli (Escherichia coli (n = 7), Klebsiella pneumoniae (n = 6) and Pseudomonas aeruginosa (n = 7)) with and without resistance mechanisms was examined by Danish (n = 1), Finnish (n = 6), Norwegian (n = 16) and Swedish (n = 5) laboratories. Minimum inhibitory concentrations (MICs) were determined for 12 antimicrobials with automated systems and compared with MICs obtained with gold standard broth microdilution. The automated systems used were VITEK 2 (n = 23), Phoenix (n = 4), MicroScan (n = 1), and ARIS (n = 1). Very major errors were identified for six antimicrobials; cefotaxime (6.9%), meropenem (0.4%), ciprofloxacin (0.7%), ertapenem (4.3%), amikacin (3.4%) and colistin (6.4%). Categorical agreement of MIC for the automated systems compared to broth microdilution ranged from 83% for imipenem to 100% for ampicillin and trimethoprim-sulfamethoxazole. The analysis revealed several important antimicrobials where resistance was underestimated, potentially with significant consequences in patient treatment. The results cast doubt on the use of automated AST in the management of patients with serious infections and suggests that more work is needed to define their limitations.

Keywords: Automated antimicrobial susceptibility testing; EUCAST; NordicAST; carbapenems; cephalosporins; colistin.

PubMed Disclaimer

References

    1. Kothari A, Morgan M, Haake DA. Emerging technologies for rapid identification of bloodstream pathogens. Clin Infect Dis. 2014;59:272-278.
    1. Van Heuverswyn J, Valik JK, Desirée van der Werff S, Hedberg P, Giske C, Nauclér P. Association between time to appropriate antimicrobial treatment and 30-day mortality in patients with bloodstream infections: a retrospective cohort study. Clin Infect Dis. 2023;76:469-478.
    1. Trotter AJ, Aydin A, Strinden MJ, O'Grady J. Recent and emerging technologies for the rapid diagnosis of infection and antimicrobial resistance. Curr Opin Microbiol. 2019;51:39-45.
    1. O'Neill J. Rapid diagnostics: stopping unnecessary use of antibiotics. London: Wellcome Trust; 2015.
    1. Lamy B, Sundqvist M, Idelevich EA. Bloodstream infections - standard and progress in pathogen diagnostics. Clin Microbiol Infect. 2020;26:142-150.

Publication types

LinkOut - more resources