Comparative study of coronary flow reserve, coronary anatomy and results of radionuclide exercise tests in patients with coronary artery disease
- PMID: 3760377
- DOI: 10.1016/s0735-1097(86)80377-1
Comparative study of coronary flow reserve, coronary anatomy and results of radionuclide exercise tests in patients with coronary artery disease
Abstract
A comparative assessment of regional coronary flow reserve, quantitative percent diameter coronary stenosis and exercise-induced perfusion and wall motion abnormalities was performed in 39 patients with coronary artery disease. Coronary flow reserve was determined by a digital angiographic technique utilizing contrast medium as the hyperemic agent. Percent diameter stenosis was calculated by an automated quantification program applied to orthogonal cineangiograms. Thallium-201 scintigraphy and radionuclide ventriculography were used to assess regional perfusion and wall motion abnormalities, respectively, at rest and during exercise. In Group A, 19 patients without transmural infarction or collateral vessels, coronary flow reserve was inversely related to percent diameter stenosis (r = -0.61, p less than 0.0001), and scintigraphic abnormalities occurred only in vascular distributions with a coronary flow reserve of less than 2.00. There was a strong relation among abnormal regional exercise results, stenoses greater than 50% and reactive hyperemia of less than 2.00. Patients with multivessel disease, however, often had normal exercise scintigrams in regions associated with greater than 50% stenosis and low coronary flow reserve when other regions had a lower coronary flow reserve or higher grade stenosis, or both. In Group B, 20 patients with angiographically visible collateral vessels, 12 of whom had prior myocardial infarction, coronary flow reserve correlated less well with percent diameter stenosis than in Group A (r = -0.47, p less than 0.004). As in Group A patients, there was a significant relation between abnormal exercise test results and stenoses greater than 50%. However, reactive hyperemia values were generally lower than in Group A, and positive exercise stress results were strongly correlated only with highly impaired flow reserves of 1.3 or less. In Group B patients, the coronary flow reserve of vessels with less than 50% stenosis was significantly lower than that of similar vessels in Group A patients (2.40 +/- 0.79 versus 1.56 +/- 0.43; p less than 0.0002). It is concluded that: there is a general relation between quantitative percent diameter stenosis and reactive hyperemia that is not of sufficient precision to allow accurate prediction of coronary flow reserve in individual cases; exercise scintigraphic abnormalities are usually associated with low coronary flow reserve, and the relation between these two functional tests is stronger than the relation between exercise test results and quantitative percent diameter stenosis.(ABSTRACT TRUNCATED AT 400 WORDS)
Similar articles
-
Which cineangiographically assessed anatomic variable correlates best with functional measurements of stenosis severity? A comparison of quantitative analysis of the coronary cineangiogram with measured coronary flow reserve and exercise/redistribution thallium-201 scintigraphy.J Am Coll Cardiol. 1988 Sep;12(3):686-91. doi: 10.1016/s0735-1097(88)80057-3. J Am Coll Cardiol. 1988. PMID: 3403826
-
Value of exercise radionuclide ventriculography and thallium-201 scintigraphy in evaluating successful coronary angioplasty: comparison with coronary flow reserve, translesional gradient and percent diameter stenosis.Eur Heart J. 1987 Apr;8(4):329-39. doi: 10.1093/oxfordjournals.eurheartj.a062282. Eur Heart J. 1987. PMID: 2956100
-
Comparison of pressure-derived fractional flow reserve with poststenotic coronary flow velocity reserve for prediction of stress myocardial perfusion imaging results.Am Heart J. 1995 Oct;130(4):723-33. doi: 10.1016/0002-8703(95)90070-5. Am Heart J. 1995. PMID: 7572579
-
Detecting and assessing severity of coronary artery disease in humans.Cardiovasc Intervent Radiol. 1990 Feb-Mar;13(1):5-13. doi: 10.1007/BF02576930. Cardiovasc Intervent Radiol. 1990. PMID: 2111216 Review.
-
[Relevance and methods for determining coronary flow reserve].Z Kardiol. 1998;87 Suppl 2:74-9. doi: 10.1007/s003920050543. Z Kardiol. 1998. PMID: 9827464 Review. German.
Cited by
-
Are separate normal data files required for quantitative pharmacologic stress radionuclide myocardial perfusion imaging?J Nucl Cardiol. 1996 Nov-Dec;3(6 Pt 2):S31-40. doi: 10.1016/s1071-3581(96)90206-8. J Nucl Cardiol. 1996. PMID: 8989685 Review. No abstract available.
-
Validation in the canine model of a new non-invasive method of measuring coronary blood flow reserve: split dose thallium-201 rest/stress imaging.Int J Cardiovasc Imaging. 2001 Apr;17(2):145-52. doi: 10.1023/a:1010627423924. Int J Cardiovasc Imaging. 2001. PMID: 11558973
-
Transcatheter coronary artery diagnostic techniques including impedance-catheter and impedance-guidewire measurement of absolute coronary blood flow.Tex Heart Inst J. 1989;16(3):195-203. Tex Heart Inst J. 1989. PMID: 15227207 Free PMC article.
-
Correlations between quantitative cineangiography, coronary flow reserve measured with digital subtraction cineangiography and exercise thallium perfusion scintigraphy.Int J Card Imaging. 1988;3(2-3):133-9. doi: 10.1007/BF01814886. Int J Card Imaging. 1988. PMID: 3049845
-
PET and SPECT in heart failure.Curr Cardiol Rep. 2013 Mar;15(3):337. doi: 10.1007/s11886-012-0337-z. Curr Cardiol Rep. 2013. PMID: 23338719 Review.
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources
Medical
Research Materials