Randomized Controlled Trial
. 2023 Oct 17;148(16):1195-1206.
doi: 10.1161/CIRCULATIONAHA.123.066429. Epub 2023 Aug 27.

Optical Coherence Tomography-Guided or Intravascular Ultrasound-Guided Percutaneous Coronary Intervention: The OCTIVUS Randomized Clinical Trial

Affiliations
Randomized Controlled Trial

Optical Coherence Tomography-Guided or Intravascular Ultrasound-Guided Percutaneous Coronary Intervention: The OCTIVUS Randomized Clinical Trial

Do-Yoon Kang et al. Circulation. .

Abstract

Background: Intravascular imaging-guided percutaneous coronary intervention (PCI) with intravascular ultrasound (IVUS) or optical coherence tomography (OCT) showed superior clinical outcomes compared with angiography-guided PCI. However, the comparative effectiveness of OCT-guided and IVUS-guided PCI regarding clinical outcomes is unknown.

Methods: In this prospective, multicenter, open-label, pragmatic trial, we randomly assigned 2008 patients with significant coronary artery lesions undergoing PCI in a 1:1 ratio to undergo either an OCT-guided or IVUS-guided PCI. The primary end point was a composite of death from cardiac causes, target vessel-related myocardial infarction, or ischemia-driven target-vessel revascularization at 1 year, which was powered for noninferiority of the OCT group compared with the IVUS group. Safety outcomes were also assessed.

Results: At 1 year, primary end point events occurred in 25 of 1005 patients (Kaplan-Meier estimate, 2.5%) in the OCT group and in 31 of 1003 patients (Kaplan-Meier estimate, 3.1%) in the IVUS group (absolute difference, -0.6 percentage points; upper boundary of one-sided 97.5% CI, 0.97 percentage points; P<0.001 for noninferiority). The incidence of contrast-induced nephropathy was similar (14 patients [1.4%] in the OCT group versus 15 patients [1.5%] in the IVUS group; P=0.85). The incidence of major procedural complications was lower in the OCT group than in the IVUS group (22 [2.2%] versus 37 [3.7%]; P=0.047), although imaging procedure-related complications were not observed.

Conclusions: In patients with significant coronary artery lesions, OCT-guided PCI was noninferior to IVUS-guided PCI with respect to the incidence of a composite of death from cardiac causes, target vessel-related myocardial infarction, or ischemia-driven target-vessel revascularization at 1 year. The selected study population and lower-than-expected event rates should be considered in interpreting the trial.

Registration: URL: https://www.

Clinicaltrials: gov; Unique number: NCT03394079.

Keywords: cardiac imaging techniques; percutaneous coronary intervention; tomography, optical coherence; ultrasonography, interventional.

PubMed Disclaimer

Conflict of interest statement

Disclosures Dr D.-W. Park reports research grants or speaker fees from Abbott Vascular, Medtronic, and Daiichi-Sankyo; grants from ChongKunDang Pharm and Daewoong Pharm. Dr. S.-J. Park reports research grants or speaker fees from Abbott Vascular, Medtronic, Daiichi-Sankyo, ChongKunDang Pharm, Daewoong Pharm, and Edwards. All other authors declare no competing interests.

Publication types

MeSH terms

Associated data