Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Oct 1;49(10):428-432.
doi: 10.1097/ICL.0000000000001024. Epub 2023 Aug 28.

Correlation of Manifest Refraction and Simulated Keratometry to Tomography Characteristics in Patients With Keratoconus

Affiliations

Correlation of Manifest Refraction and Simulated Keratometry to Tomography Characteristics in Patients With Keratoconus

Steven A Greenstein et al. Eye Contact Lens. .

Abstract

Objectives: To report on baseline refractive and keratometric values and their correlation with tomographic characteristics of eyes with keratoconus (KC).

Methods: Retrospective chart review of patients treated in a single-center cornea and refractive surgery practice. Baseline topographic measurements were reviewed for 1,012 keratoconic eyes of 586 patients between 2008 and 2018. The manifest refraction, thinnest pachymetry (P thin ), corneal astigmatism (K astig ), and the maximum (K max ), steep (K steep ), flat (K flat ), and mean (K mean ) keratometry were analyzed. The location of K max (x, y) was used to determine central (<1 mm), paracentral (1-3 mm), pericentral (3-5 mm), or peripheral (>5 mm) cone locations.

Results: In the entire cohort, the mean manifest sphere was -2.2±4.4 diopters (D) and the cylinder was -3.2±2.3 D. In total, 48.6% of patients had against the rule (ATR) manifest astigmatism (M astig ). The average K astig was 3.8±2.7 D, and unlike the manifest axis, 50.2% of patients had with the rule (WTR) K astig . Patients with a K max less than 50 D had an M astig of -1.9±1.6 D, 45.9% of which was ATR M astig . With respect to baseline tomography measurements, K max , K steep , K flat , and K mean were 58.0±9.4, 50.6±6.5, 46.8±5.9, and 48.6±6.1 D, respectively. There was a weak correlation between K max and simulated keratometry (K steep , K flat , and K mean ) for patients with a K max less than 60 D.

Conclusions: Simulated keratometry is poorly correlated with KC severity until the disease is more severe. M astig ≥2 D and ATR M astig were correlated with KC at all levels of severity. M astig ≥2 D and ATR M astig may serve as a simple, inexpensive, and widely available indicator for topographic analysis to identify possible KC and suggest further workup; however, further prospective studies are needed to confirm its utility.

PubMed Disclaimer

Conflict of interest statement

The authors have no funding or conflicts of interest to disclose.

References

    1. Rabinowitz YS. Keratoconus. Surv Ophthalmol 1998;42:297–319.
    1. Alio JL, Shabayek MH. Corneal higher order aberrations: A method to grade keratoconus. J Refract Surg 2006;22:539–545.
    1. Jafri B, Li X, Yang H, et al. Higher order wavefront aberrations and topography in early and suspected keratoconus. J Refract Surg 2007;23:774–781.
    1. Li X, Yang H, Rabinowitz YS. Keratoconus: Classification scheme based on videokeratography and clinical signs. J Cataract Refract Surg 2009;35:1597–1603.
    1. Klyce SD. Computer-assisted corneal topography. High-resolution graphic presentation and analysis of keratoscopy. Invest Ophthalmol Vis Sci 1984;25:1426–1435.

LinkOut - more resources