Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
Multicenter Study
. 2024 Jan 29;110(4):299-305.
doi: 10.1136/heartjnl-2023-322987.

Role of lipoprotein(a) concentrations in bioprosthetic aortic valve degeneration

Affiliations
Multicenter Study

Role of lipoprotein(a) concentrations in bioprosthetic aortic valve degeneration

Juan M Farina et al. Heart. .

Abstract

Objectives: Lipoprotein(a) (Lp(a)) is associated with an increased incidence of native aortic stenosis, which shares similar pathological mechanisms with bioprosthetic aortic valve (bAV) degeneration. However, evidence regarding the role of Lp(a) concentrations in bAV degeneration is lacking. This study aims to evaluate the association between Lp(a) concentrations and bAV degeneration.

Methods: In this retrospective multicentre study, patients who underwent a bAV replacement between 1 January 2010 and 31 December 2020 and had a Lp(a) measurement were included. Echocardiography follow-up was performed to determine the presence of bioprosthetic valve degeneration, which was defined as an increase >10 mm Hg in mean gradient from baseline with concomitant decrease in effective orifice area and Doppler Velocity Index, or new moderate/severe prosthetic regurgitation. Levels of Lp(a) were compared between patients with and without degeneration and Cox regression analysis was performed to investigate the association between Lp(a) levels and bioprosthetic valve degeneration.

Results: In total, 210 cases were included (mean age 74.1±9.4 years, 72.4% males). Median time between baseline and follow-up echocardiography was 4.4 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.7%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in patients affected by degeneration versus non-affected cases: 50.0 (IQR 72.0) vs 15.6 (IQR 48.6) mg/dL, p=0.002. In the regression analysis, high Lp(a) levels (≥30 mg/dL) were associated with degeneration both in a univariable analysis (HR 3.6, 95% CI 1.7 to 7.6, p=0.001) and multivariable analysis adjusted by other risk factors for bioprostheses degeneration (HR 4.4, 95% CI 1.9 to 10.4, p=0.001).

Conclusions: High serum Lp(a) is associated with bAV degeneration. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) levels could slow bioprostheses degradation.

Keywords: Aortic Valve Stenosis; Echocardiography; Heart Valve Prosthesis Implantation; Hyperlipidaemias; Transcatheter Aortic Valve Replacement.

PubMed Disclaimer

Conflict of interest statement

Competing interests: None declared.

Publication types

LinkOut - more resources