. 2023 Dec;39(12):2419-2426.
doi: 10.1007/s10554-023-02939-2. Epub 2023 Sep 2.

Reproducibility of transthoracic 3D echocardiography in the assessment of mitral valve area in patients with rheumatic mitral stenosis: real time versus ECG-gated 3D echocardiography

Affiliations

Reproducibility of transthoracic 3D echocardiography in the assessment of mitral valve area in patients with rheumatic mitral stenosis: real time versus ECG-gated 3D echocardiography

Nidhal Bouchahda et al. Int J Cardiovasc Imaging. 2023 Dec.

Abstract

Purpose: To assess reproducibility of Real time 3D echocardiography (RT3D) and ECG-gated 3D echocardiography (EG3D) when measuring the mitral valve area (MVA) in rheumatic mitral stenosis (MS).

Methods: MVA was assessed by three operators in 68 MS patients using RT3D and EG3D. Reproducibility of each technique was determined by calculating the standard error of measurements (SEM).

Results: SEM was similar between RT3D and EG3D. MVA variability was of 0.4 cm² or 30% of any RT3D or EG3D measured MVA. The minimal change in MVA above which two measurements should be considered to differ significantly for the same operator was of 0.4 cm² for RT3D and 0.5 cm² for EG3D. For two different operators making successive measurements, the minimum significant change was of 0.5 cm² for RT3D and 0.6 cm² for EG3D. The minimum significant difference when switching from RT3D to EG3D or vice versa is of 0.6 cm². Low temporal resolution of 6 Hz has the least variability when using RT3D (0.19 cm² vs. 0.26 cm², p = 0.009) but significantly underestimated MVA (1.3 ± 0.4 cm² vs. 1.4 ± 0.4 cm², p < 10- 3) when compared to EG3D. MVA variability was significantly higher in mild MS when compared to severe MS whether it is RT3D (0.23 cm² vs. 0.18 cm², p = 0.02) or EG3D (0.27 cm² vs. 0.16 cm², p < 0.001).

Conclusion: RT3D and EG3D are equally reproducible in the assessment of MVA in patients with MS. Further measurements standardization is required to have a clinically acceptable estimations of the true 3D MVA and minimal detectable differences.

Keywords: Echocardiography; Four-Dimensional; Mitral valve stenosis.

PubMed Disclaimer

References

    1. Sebag IA, Morgan JG, Handschumacher MD, Marshall JE, Nesta F, Hung J et al (2005) Usefulness of three-dimensionally guided Assessment of mitral stenosis using matrix-array Ultrasound. Am J Cardiol 96:1151–1156 - DOI - PubMed
    1. Cordeiro P, Sugeng L, Isla LP, De, Weinert L, Macaya C, Rodrı E et al (2004) Real-time Three-Dimensional Echocardiography for rheumatic mitral valve stenosis evaluation an Accurate and Novel Approach. J Am Coll Cardiol 43(11):2091–2096 - DOI - PubMed
    1. Lang RM, Badano LP, Tsang W, Adams DH, Agricola E, Buck T et al (2012) EAE / ASE Recommendations for Image Acquisition and Display using Three-Dimensional Echocardiography. Eur Heart J Cardiovasc Imaging 13:1–46 - DOI - PubMed
    1. Vegas A (2016) Three-dimensional transesophageal echocardiography: principles and clinical applications. Ann Card Anaesth 19(5):S35–43 - DOI - PubMed - PMC
    1. Schlosshan D, Aggarwal G, Ed BSCM, Mathur G, Allan R, Cranney G (2011) Real-time 3D transesophageal echocardiography for the evaluation of rheumatic mitral stenosis. JACC Cardiovasc Imaging 4(6):580–588 - DOI - PubMed

MeSH terms

LinkOut - more resources