Flow characteristics of four commonly used mechanical heart valves
- PMID: 3766415
- DOI: 10.1016/0002-9149(86)90349-8
Flow characteristics of four commonly used mechanical heart valves
Abstract
The in vivo and in vitro fluid dynamic performance of 4 mechanical heart valves was reviewed: Starr-Edwards silicon-rubber ball valves (models 1200/1260 aortic and 6120 mitral valves), Björk-Shiley tilting disc valves (standard spherical model, modified and unmodified convexo-concave [60 degrees and 70 degrees C-C] models), the Medtronic-Hall (Hall-Kaster) tilting disc valve and the St. Jude Medical bileaflet valve. These valves were chosen because of their past or present popularity in clinical use and because they encompass most of the basic mechanical valve designs used during the past 2 decades. The flow measurements reported include in vivo and in vitro mean pressure drop, cardiac output or cardiac index, regurgitant volume, effective orifice area and performance index.
Similar articles
-
Aortic Valve Replacement.2023 May 29. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. 2023 May 29. In: StatPearls [Internet]. Treasure Island (FL): StatPearls Publishing; 2025 Jan–. PMID: 30725821 Free Books & Documents.
-
An emergency physician's guide to prosthetic heart valves: identification and hemodynamic function.Ann Emerg Med. 1988 Mar;17(3):194-200. doi: 10.1016/s0196-0644(88)80105-7. Ann Emerg Med. 1988. PMID: 3345013
-
Advances in prosthetic heart valves: fluid mechanics of aortic valve designs.J Biomater Appl. 1988 Apr;2(4):579-614. doi: 10.1177/088532828700200405. J Biomater Appl. 1988. PMID: 2974076
-
Current status of the Beall, Bjork-Shiley, Braunwald-Cutter, Lillehei-Kaster and Smeloff-Cutter cardiac valve prostheses.Am J Cardiol. 1975 Jun;35(6):855-65. doi: 10.1016/0002-9149(75)90122-8. Am J Cardiol. 1975. PMID: 124127 Review.
-
Mechanical cardiac valvular prostheses.Ann Thorac Surg. 1991 Jul;52(1):161-72. doi: 10.1016/0003-4975(91)91453-3. Ann Thorac Surg. 1991. PMID: 2069453 Review.
Cited by
-
Possible Assessment of Calf Venous Pump Efficiency by Computational Fluid Dynamics Approach.Front Physiol. 2020 Sep 8;11:1003. doi: 10.3389/fphys.2020.01003. eCollection 2020. Front Physiol. 2020. PMID: 33013438 Free PMC article.
-
[Hemodynamic evaluations of patients with small aortic annulus with St. Jude Medical prosthetic heart valve].Jpn J Thorac Cardiovasc Surg. 1998 Dec;46(12):1285-91. doi: 10.1007/BF03217917. Jpn J Thorac Cardiovasc Surg. 1998. PMID: 10037837 Japanese.
-
Doppler sonographic evaluation of mechanical and bioprosthetic mitral valve prostheses during exercise with a rate corrected pressure half time.Br Heart J. 1992 Jun;67(6):466-9. doi: 10.1136/hrt.67.6.466. Br Heart J. 1992. PMID: 1622696 Free PMC article.
-
Quantitative applications of Doppler cardiography in congenital heart disease.Cardiovasc Intervent Radiol. 1987;10(6):332-47. doi: 10.1007/BF02577344. Cardiovasc Intervent Radiol. 1987. PMID: 3123059 Review.
-
Left ventricular dynamics after aortic valve replacement: a long-term, combined radionuclide angiographic and ultrasonographic study.Tex Heart Inst J. 1992;19(2):97-106. Tex Heart Inst J. 1992. PMID: 15227421 Free PMC article.
Publication types
MeSH terms
Grants and funding
LinkOut - more resources
Full Text Sources
Miscellaneous