Influence of dental implant/mini-implant design on stress distribution in overdentures: a systematic review
- PMID: 37665393
- DOI: 10.1007/s10006-023-01177-z
Influence of dental implant/mini-implant design on stress distribution in overdentures: a systematic review
Abstract
Purpose: Critically evaluate the existing literature and answer the question, "Does the dental implant/mini-implant design influence the stress distribution in prosthetic overdentures according to finite element analysis?".
Methods: This systematic review was registered in the Open Science Framework (osf.io/2bquj) and followed the PRISMA protocols. The custom search strategy was applied to 4 databases. In vitro experimental studies that evaluated the influence of dental implant/mini-implant design on stress distribution in overdentures by FEM, without time and language restrictions, were included. The selection process was carried out in two stages by two reviewers independently. Risk of bias analysis was performed by a checklist of important parameters.
Results: Sixty articles were evaluated by their title and abstract, four were selected for full reading, three were relevant, and nine were included by additional search. The 12 studies have a low risk of bias. The meta-analysis could not be performed due to the heterogeneity of the data (implant type, design variation, load intensity, and direction).
Conclusion: It can be inferred from the evaluated literature that design modifications influence the stress distribution, but as the FEM presents limitations inherent to the in vitro study, clinical trials are necessary to infer the effectiveness of the modifications. It should be noted that there is no consensus on which is the best thread design and that implants with a very narrow diameter are subject to the highest stress concentration.
Keywords: Dental implants; Finite element method; Overdenture; Stress distribution.
© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
References
-
- Pisani MX, Presotto AGC, Mesquita MF et al (2018) Biomechanical behavior of 2-implant– and single-implant–retained mandibular overdentures with conventional or mini implants. J Prosthet Dent 120:421–430. https://doi.org/10.1016/j.prosdent.2017.12.012 - DOI - PubMed
-
- Desai SR, Desai MS, Katti G, Karthikeyan I (2012) Evaluation of design parameters of eight dental implant designs : a two ‑ dimensional finite element analysis. 15:
-
- Tardelli JDC, da Costa Valente ML, Macedo AP, dos Reis AC (2021) Evaluation of biomechanical and stress distribution of different dental implant designs: primary stability and photoelastic analysis. IRBM. https://doi.org/10.1016/j.irbm.2021.01.003
-
- Hisam MJ, Zaman I, Sharif S et al (2019) Finite element analysis of mini implant biomechanics on peri-implant bone. Procedia Manuf 30:308–314. https://doi.org/10.1016/j.promfg.2019.02.044 - DOI
-
- Valente MLC, Bolfarini C, Oliveira De DP (2014) Dental mini-implant designs to support overdentures : development, biomechanical evaluation, and 3D digital image correlation. J Prosthet Dent 128(4):754–63. https://doi.org/10.1016/j.prosdent.2020.06.043 - DOI
Publication types
MeSH terms
Substances
LinkOut - more resources
Full Text Sources