Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Jul;15(Suppl 2):S910-S912.
doi: 10.4103/jpbs.jpbs_54_23. Epub 2023 Apr 28.

An In-vitro Evaluation of Retention Force of All PEEK, All Zirconia and Zirconia-PEEK Telescopic Attachment for Mandibular Overdentures

Affiliations

An In-vitro Evaluation of Retention Force of All PEEK, All Zirconia and Zirconia-PEEK Telescopic Attachment for Mandibular Overdentures

Gujjalapudi Mahalakshmi et al. J Pharm Bioallied Sci. 2023 Jul.

Abstract

The objective of this study is to compare retention capacity of mandibular implant-supported overdenture with all zirconia, zirconia-PEEK, and all PEEK telescopic attachments. Sixty acrylic resin models of mandible were used. Telescopic attachment system was made up of all zirconia, all PEEK, and zirconia-PEEK. Evaluation of retention force was done using universal testing machine. Obtained data were statistically evaluated. Highest initial force value was obtained with zirconia-PEEK group. All PEEK and zirconia-PEEK groups showed significantly decreased final retention values in comparison to their initial values. Zirconia can be regarded as the material of choice for telescopic crown, whereas polyetheretherketone and zirconia-PEEK telescopic crowns showed retention loss over a period of time.

Keywords: Overdenture; PEEK; retention force; zirconia.

PubMed Disclaimer

Conflict of interest statement

There are no conflicts of interest.

References

    1. Bueno-Samper A, Hernández-Aliaga M, Calvo-Guirado JL. The implant supported milled bar overdenture:A literature review. Med Oral Patol Oral Cir Bucal. 2010;15:375–8. - PubMed
    1. Uludag B, Sahin V, Ozturk O. Fabrication of zirconium primary copings to provide retention for a mandibular telescopic overdenture:A clinical report. Int J Prosthodont. 2008;21:509–10. - PubMed
    1. Manicone P, Iommetti P, Raffaelli L. An overview of zirconia ceramics:Basic properties and clinical applications. J Dent. 2007;35:819–26. - PubMed
    1. ElCharkawi H, Zekry K, Elwaked M. Stress analysis of different osseointegrated implants supporting distal extension prosthesis. J Prosthet Dent. 1994;72:614–22. - PubMed
    1. Ebadian B, Talebi S, Khodaeian N, Farzin M. Stress analysis of mandibular implant-retained overdenture with independent attachment system:Effect of restoration space and attachment height. Gen Dent. 2015;63:61–7. - PubMed