Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Jan;95(1):293-301.
doi: 10.1038/s41390-023-02817-6. Epub 2023 Sep 19.

Early cardiac function and death, severe bronchopulmonary dysplasia and pulmonary hypertension in extremely preterm infants

Affiliations

Early cardiac function and death, severe bronchopulmonary dysplasia and pulmonary hypertension in extremely preterm infants

Shiran S Moore et al. Pediatr Res. 2024 Jan.

Abstract

Background: Association between early cardiac function and neonatal outcomes are scarcely reported. The aim of the current study was to describe this association with death, severe bronchopulmonary dysplasia (BPD) and BPD-related pulmonary hypertension (PH).

Methods: Retrospective cohort study of infants <29 weeks born between 2015 and 2019. Infants with clinically acquired echocardiography at ≤21 days after birth were included and data were extracted by an expert masked to outcomes.

Results: A total of 176 infants were included. Echocardiogram was performed at a median of 9 days (IQR 5-13.5). Of these, 31 (18%) had death/severe BPD and 59 (33.5%) had death/BPD-related PH. Infants with death/severe BPD were of lower birth weight (745 [227] vs 852 [211] grams, p = 0.01) and more exposed to invasive ventilation, late-onset sepsis, inotropes and/or postnatal steroids. Early echocardiograms demonstrated decreased right ventricular [Tricuspid Annular Plane Systolic Excursion: 5.2 (1.4) vs 6.2 (1.5) cm, p = 0.03] and left ventricular function [Ejection fraction 53 (14) vs 58 (10) %, p = 0.03]. Infants with death/BPD-related PH had an increased Eccentricity index (1.35 [0.20] vs 1.26 [0.19], p = 0.02), and flat/bowing septum (19/54 [35%] vs 20/109 [18%], p = 0.021).

Conclusions: In extremely premature infants, altered ventricular function and increased pulmonary pressure indices within the first 21 days after birth, were associated with the combined outcome of death/severe BPD and death/BPD-related PH.

Impact: Decreased cardiac function on echocardiography performed during first three weeks of life is associated with severe bronchopulmonary dysplasia in extremely premature infants. In extreme preterm infants, echocardiographic signs of pulmonary hypertension in early life are associated with later BPD-related pulmonary hypertension close to 36 weeks post-menstrual age. Early cardiac markers should be further studied as potential intervention targets in this population. Our study is adding comprehensive analysis of echocardiographic data in infants born below 29 weeks gestational age.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Mourani, P. M. et al. Early pulmonary vascular disease in preterm infants at risk for bronchopulmonary dysplasia. Am. J. Respir. Crit. Care Med. 191, 87–95 (2015). - PubMed - PMC - DOI
    1. Morty, R. E. Recent advances in the pathogenesis of Bpd. Semin Perinatol. 42, 404–412 (2018). - PubMed - DOI
    1. Stoll, B. J. et al. Trends in care practices, morbidity, and mortality of extremely preterm neonates, 1993–2012. JAMA 314, 1039–1051 (2015). - PubMed - PMC - DOI
    1. Alvarez-Fuente, M. et al. Exploring clinical, echocardiographic and molecular biomarkers to predict bronchopulmonary dysplasia. PLoS One 14, e0213210 (2019). - PubMed - PMC - DOI
    1. Bancalari, E. & Claure, N. Definitions and diagnostic criteria for bronchopulmonary dysplasia. Semin Perinatol. 30, 164–170 (2006). - PubMed - DOI

LinkOut - more resources