Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Jan 5:461:132561.
doi: 10.1016/j.jhazmat.2023.132561. Epub 2023 Sep 15.

Novel molecularly imprinted nanogel modified microfluidic paper-based SERS substrate for simultaneous detection of bisphenol A and bisphenol S traces in plastics

Affiliations

Novel molecularly imprinted nanogel modified microfluidic paper-based SERS substrate for simultaneous detection of bisphenol A and bisphenol S traces in plastics

Mirkomil Sharipov et al. J Hazard Mater. .

Abstract

Paper-based surface-enhanced Raman scattering (SERS) optical nanoprobes provide ultrasensitive analyte detection; however, they lack selectivity, making them difficult to use in real-world sample analysis without a pretreatment process. This work describes the design of a microfluidic paper-based SERS substrate based on molecularly imprinted nanogels decorated with silver nanoparticles to simultaneously detect bisphenol A (BPA) and bisphenol S (BPS) traces in plastic toys and receipts. The synthesized nanogels have two characteristics that boost SERS performance: molecularly imprinted cavities that allow for selective adsorption and a wrinkled surface that creates uniformly distributed hot spots. Simple paper-based sensor devices were built as 'drop and read' SERS substrates with a separate reservoir to detect a single target, while advanced SERS platforms were designed as a microfluidic chip with two reservoirs connected by a channel for simultaneous detection of BPA and BPS. The SERS platform with a single reservoir showed outstanding analytical performance for the detection of BPA and BPS, with low detection limits of 0.38 pM and 0.37 pM, respectively. The microfluidic paper-based sensor allowed simultaneous and selective detection of BPA and BPS with detection limits estimated at 0.68 nM and 0.47 nM, respectively. The developed sensors are successfully applied to detect BPA and BPS in plastic products and receipts. Finally, the results obtained with our method showed greater sensitivity than those of commercially available ELISA kits, and the acquired values within the ELISA detection range were in excellent agreement.

Keywords: Bisphenols; MIP nanogel; Microfluidic paper-based analytical device; Nanowrinkles; SERS.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Publication types

LinkOut - more resources