Effect of shape of automatic dose rate control and wedge compensation filter on radiation dose in an angiography system with a flat-panel detector
Abstract
The purpose was to investigate air-kerma area product (PKA) and entrance surface air-kerma rate ([Formula: see text]a,e) on the effect of the shape of automatic dose rate control (ADRC) in the presence of a wedge compensation filter. We compared and evaluated the variability of the X-ray output using a combination of wedge compensation filters and the ADRC. Two ADRC shapes (round and square) and three poly-methyl-methacrylate thicknesses (15, 20, and 25 cm) were used. A wedge compensation filter was inserted 2 cm at a time, up to 6 cm. When the wedge compensation filter was inserted to 6 cm for 20 cm of poly-methyl-methacrylate, the X-ray output fluctuated significantly. The PKA was reduced by 39% when the wedge compensation filter was inserted to 6 cm and by 59% when it was inserted to 4 cm under round-type for 20 cm poly-methyl-methacrylate. The shape of the ADRC affects [Formula: see text]a,e and PKA.
Keywords: Air-kerma area product; Angiography; Auto-dose rate control; Spectral shaping filter; Wedge compensation filter.
© 2023. The Author(s), under exclusive licence to Japanese Society of Radiological Technology and Japan Society of Medical Physics.
Similar articles
-
[Evaluation of Radiation Dose and Image Quality for Angiographic System with Spectral Shaping Filter].Nihon Hoshasen Gijutsu Gakkai Zasshi. 2019;75(1):13-23. doi: 10.6009/jjrt.2019_JSRT_75.1.13. Nihon Hoshasen Gijutsu Gakkai Zasshi. 2019. PMID: 30662028 Japanese.
-
A study of the impact of x-ray tube performance on angiography system imaging efficiency.Phys Med Biol. 2020 Nov 24;65(22):225028. doi: 10.1088/1361-6560/abbb7a. Phys Med Biol. 2020. PMID: 33231200
-
Effect of equalization filters on measurements with kerma-area product meter in a cardiovascular angiography system.J Appl Clin Med Phys. 2021 Dec;22(12):177-185. doi: 10.1002/acm2.13444. Epub 2021 Oct 5. J Appl Clin Med Phys. 2021. PMID: 34610646 Free PMC article.
-
Radiation dose and image quality in diagnostic radiology. Optimization of the dose-image quality relationship with clinical experience from scoliosis radiography, coronary intervention and a flat-panel digital detector.Acta Radiol Suppl. 2002 Mar;43(427):1-43. Acta Radiol Suppl. 2002. PMID: 12108231 Review.
-
Review and investigation of automatic brightness/dose rate control logic of fluoroscopic imaging systems in cardiovascular interventional angiography.Radiol Phys Technol. 2022 Mar;15(1):6-24. doi: 10.1007/s12194-022-00649-3. Epub 2022 Jan 20. Radiol Phys Technol. 2022. PMID: 35050444 Review.
Cited by
-
Effectiveness of wedge filter application in reducing lens radiation dose during diagnostic cerebral angiography: a phantom and prospective study.Eur Radiol. 2025 Apr 26. doi: 10.1007/s00330-025-11617-x. Online ahead of print. Eur Radiol. 2025. PMID: 40285813
References
-
- Hajiha M, Smith J, Amasyali AS, Groegler J, Shah M, Alsyouh M, Krause A, You H, Brown J, Li A, Goyne A, Baldwin DD, Stokes P, Hsi R, Baldwin DD. The effect of operative field instrument clutter during intraoperative fluoroscopy on radiation exposure. J Endourol. 2019;33(8):626–33. https://doi.org/10.1089/end.2019.0285 . - DOI - PubMed
-
- Suleiman OH, Conway BJ, Quinn P, Antonsen RG, Slayton RJ, Spelic DC. Nationwide survey of fluoroscopy: radiation dose and image quality. Radiology. 1997;203(2):471–6. https://doi.org/10.1148/radiology.203.2.9114107 . - DOI - PubMed
-
- Kuon E, Glaser C, Dahm JB. Effective techniques for reduction of radiation dosage to patients undergoing invasive cardiac procedures. Br J Radiol. 2003;76(906):406–13. https://doi.org/10.1259/bjr/82051842 . - DOI - PubMed
-
- Stephen R, Daniel RB. Minimizing radiation dose to patient and staff during fluoroscopic, nasoenteral tube insertions. Br J Radiol. 1992;65(770):162–6. https://doi.org/10.1259/0007-1285-65-770-162 . - DOI
-
- Axelsson B. Optimisation in fluoroscopy. Biomed Imaging Interv J. 2007;3(2):1–5. https://doi.org/10.2349/biij.3.2.e47 . - DOI
MeSH terms
Substances
LinkOut - more resources
Full Text Sources