. 2023 Nov;415(27):6723-6731.
doi: 10.1007/s00216-023-04949-4. Epub 2023 Sep 21.

Bimodal persistent luminescence for autofluorescence-free ratiometric biosensing

Affiliations

Bimodal persistent luminescence for autofluorescence-free ratiometric biosensing

Wenjing Dai et al. Anal Bioanal Chem. 2023 Nov.

Abstract

In optical biosensing, analyte-independent factors such as autofluorescence interference and excitation source fluctuation decrease the sensitivity and accuracy. Herein, we reported a bimodal persistent luminescence strategy to design dual-emissive persistent luminescence nanoparticles (PLNPs) with built-in self-calibration to preclude interference from analyte-independent factors in biosensing. As a proof of concept, ZnGa2O4:Cr PLNPs with emissions at both 490 nm and 695 nm were designed. The I490/I695 ratio of ZnGa2O4:Cr was readily adjusted by simply changing the doping concentration of Cr3+. The ZnGa2O4:Cr PLNPs were employed for the ratiometric detection of urinary mesna. A good linear relationship between the I490/I695 ratio of ZnGa2O4:Cr-based nanoprobe and the concentration of mesna was obtained in the range of 0-40 μM. The limit of detection was about 0.40 μM. Results showed that autofluorescence interference from urine was totally eliminated by collecting the persistent luminescence signal of ZnGa2O4:Cr after excitation ceased. Moreover, the built-in self-calibration feature of the ratiometric ZnGa2O4:Cr PLNPs efficiently suppressed the interference from fluctuations in instrumental parameters during urinary mesna detection. The recovery rates of mesna in the spiked urine samples are in the range of 99.1~109.0%, showing the reliability of the ratiometric ZnGa2O4:Cr PLNPs in urinary mesna detection. ZnGa2O4:Cr can further be expanded to the detection of other analytes in complex matrices. This study may open new opportunities for the design of dual-emissive PLNPs with tunable ratios of emission intensity, and it can further promote the applications of optical biosensing in disease diagnosis, food safety, and environmental monitoring.

Keywords: Autofluorescence; Optical biosensing; Persistent luminescence; Ratiometric.

PubMed Disclaimer

Similar articles

Cited by

References

    1. Wang K, Liu C, Zhu H, Zhang Y, Su M, Wang X, et al. Recent advances in small-molecule fluorescent probes for diagnosis of cancer cells/tissues. Coordin Chem Rev. 2023;477: 214946. - DOI
    1. Wang L, Han S, Li C, Tu D, Chen X. Lanthanide-doped inorganic nanoprobes for luminescent assays of biomarkers. Acc Mater Res. 2023;4(2):193–204. - DOI
    1. Zeng Z, Liew SS, Wei X, Pu K. Hemicyanine-based near-infrared activatable probes for imaging and diagnosis of diseases. Angew Chem Int Ed. 2021;60(51):26454–75. - DOI
    1. Liu J, Lécuyer T, Seguin J, Mignet N, Scherman D, Viana B, et al. Imaging and therapeutic applications of persistent luminescence nanomaterials. Adv Drug Deliv Rev. 2019;138:193–210. - PubMed - DOI
    1. Zhang KY, Yu Q, Wei H, Liu S, Zhao Q, Huang W. Long-lived emissive probes for time-resolved photoluminescence bioimaging and biosensing. Chem Rev. 2018;118(4):1770–839. - PubMed - DOI

LinkOut - more resources