Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Dec 1;37(12):607-613.
doi: 10.1097/BOT.0000000000002698.

Iliosacral Screws Can Be Placed With Precision by Adjusting the Pelvic Inlet Between S1 and S2

Affiliations

Iliosacral Screws Can Be Placed With Precision by Adjusting the Pelvic Inlet Between S1 and S2

David A Zuelzer et al. J Orthop Trauma. .

Abstract

Objectives: To determine (1) the natural incidence of sacral inlet angle differences between S1 and S2 and (2) implications for iliosacral screw placement with a technique to improve the accuracy of the intraoperative fluoroscopic inlet for S1 and S2.

Design: Combined retrospective and prospective cohort reviews.

Setting: Regional Level 1 trauma center.

Patients/participants: After exclusion criteria, 300 patients with uninjured pelvic rings to determine the natural incidence of S1-S2 angle differences and 33 patients treated with iliosacral screws over the study period.

Intervention: None in the retrospective cohort. In the prospective cohort, all patients underwent fluoroscopically assisted iliosacral screw fixation.

Main outcome measurements: Radiographic determination of S1-S2 angle differences above 10 degrees in a natural population for the retrospective cohort. In the prospective, operative cohort, the outcome of interest was the safety of iliosacral screws in S1 and S2 as determined on intraoperative fluoroscopy and postoperative CT scan.

Results: In the retrospective cohort, 180 of 300 (60.0%) had S1-S2 inlet angle differences above 10 degrees. In the operative cohort, 19 of 33 (57.6%) had S1-S2 inlet angle differences above 10 degrees. Of the iliosacral screws in S1 and S2 placed using the described imaging technique, all (69/69, 100%) were safe.

Conclusions: A normal population determined that differences in the inlet angle between S1 and S2 are common. An operative cohort was treated using preoperative CT-based planning to define different intraoperative fluoroscopic inlet views for S1 and S2, if a larger difference existed. Using this technique, 69 of 69 (100%) iliosacral screws were safe.

Level of evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Keywords: iliosacral screws; inlet; pelvis; percutaneous; safety.

PubMed Disclaimer

Conflict of interest statement

The authors report no conflict of interest.

References

    1. Simonian PT, Chip Routt M. Biomechanics of pelvic fixation. Orthop Clin North Am. 1997;28:351–367.
    1. Chip Routt M, Simonian PT, Swiontkowski MF. Stabilization of pelvic ring disruptions. Orthop Clin North Am. 1997;28:369–388.
    1. Routt ML, Kregor PJ, Simonian PT, et al. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995;9:207–214.
    1. Kregor PJ, Routt ML, Unstable pelvic ring disruptions in unstable patients. Injury. 1999;30(suppl 2):B19–B28.
    1. Barei DP, Bellabarba C, Mills W, et al. Percutaneous management of unstable pelvic ring disruptions. Injury. 2001;32(suppl 1):SA33–SA44.