Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Nov;32(11):107297.
doi: 10.1016/j.jstrokecerebrovasdis.2023.107297. Epub 2023 Sep 20.

CTP-based estimated ischemic core: A comparative multicenter study between Olea and RAPID software

Affiliations

CTP-based estimated ischemic core: A comparative multicenter study between Olea and RAPID software

V Yedavalli et al. J Stroke Cerebrovasc Dis. 2023 Nov.

Abstract

Background and purpose: CTP is increasingly used to assess eligibility for endovascular therapy (EVT) in patients with large vessel occlusions (LVO). There remain variability and inconsistencies between software packages for estimation of ischemic core. We aimed to use heterogenous data from four stroke centers to perform a comparative analysis for CTP-estimated ischemic core between RAPID (iSchemaView) and Olea (Olea Medical).

Methods: In this retrospective multicenter study, patients with anterior circulation LVO who underwent pretreatment CTP, successful EVT (defined TICI ≥ 2b), and follow-up MRI included. Automated CTP analysis was performed using Olea platform [rCBF < 25% and differential time-to-peak (dTTP)>5s] and RAPID (rCBF < 30%). The CTP estimated core volumes were compared against the final infarct volume (FIV) on post treatment MRI-DWI.

Results: A total of 151 patients included. The CTP-estimated ischemic core volumes (mean ± SD) were 18.7 ± 18.9 mL on Olea and 10.5 ± 17.9 mL on RAPID significantly different (p < 0.01). The correlation between CTP estimated core and MRI final infarct volume was r = 0.38, p < 0.01 for RAPID and r = 0.39, p < 0.01 for Olea. Both software platforms demonstrated a strong correlation with each other (r = 0.864, p < 0.001). Both software overestimated the ischemic core volume above 70 mL in 4 patients (2.6%).

Conclusions: Substantial variation between Olea and RAPID CTP-estimated core volumes exists, though rates of overcalling of large core were low and identical. Both showed comparable core volume correlation to MRI infarct volume.

Keywords: Acute ischemic stroke; CT perfusion; Endovascular thrombectomy; Large vessel occlusion.

PubMed Disclaimer

Conflict of interest statement

Declaration of Competing Interest Vivek Yedavalli, consultant, RAPID (IschemaView) Kambiz Nael, consultant, Olea Medical, Brainomix Jeffery Saver, consultant, RAPID (IschemaView) David Liebeskind, ConsultantOlea Medical Achala Vagal, Consultant, Viz AI Ashok Srinivasan, GE Healthcare

LinkOut - more resources