Significance of Neonatal Heart Rate in the Delivery Room-A Review
- PMID: 37761512
- PMCID: PMC10528538
- DOI: 10.3390/children10091551
Significance of Neonatal Heart Rate in the Delivery Room-A Review
Erratum in
-
Correction: Nerdrum Aagaard et al. Significance of Neonatal Heart Rate in the Delivery Room-A Review. Children2023, 10, 1551.Children (Basel). 2024 Jan 18;11(1):120. doi: 10.3390/children11010120. Children (Basel). 2024. PMID: 38255439 Free PMC article.
Abstract
Background: Heart rate (HR) is considered the main vital sign in newborns during perinatal transition, with a threshold of 100 beats per minute (bpm), below which, intervention is recommended. However, recent changes in delivery room management, including delayed cord clamping, are likely to have influenced normal HR transition.
Objective: To summarize the updated knowledge about the factors, including measurement methods, that influence HR in newborn infants immediately after birth. Additionally, this paper provides an overview of delivery room HR as a prognostic indicator in different subgroups of newborns.
Methods: We searched PubMed, EMBASE, and Google Scholar with the terms infant, heart rate, delivery room, resuscitation, pulse oximetry, and electrocardiogram.
Results: Seven studies that described HR values in newborn infants immediately after birth were included. Pulse oximetry-derived HR percentiles after immediate cord clamping may not be applicable to the current practice of delayed cord clamping and the increasing use of delivery room electrocardiograms. Mask ventilation may adversely affect HR, particularly in premature and non-asphyxiated infants. Prolonged bradycardia is a negative prognostic factor, especially if combined with hypoxemia in infants <32 weeks of gestation.
Conclusions: HR assessment in the delivery room remains important. However, the cardiopulmonary transition is affected by delayed cord clamping, gestational age, and underlying conditions.
Keywords: electrocardiogram; heart rate; infants; neonatal resuscitation; newborn; pulse oximetry.
Conflict of interest statement
The authors declare no conflict of interest.
Similar articles
-
Physiologically based cord clamping for infants ≥32+0 weeks gestation: A randomised clinical trial and reference percentiles for heart rate and oxygen saturation for infants ≥35+0 weeks gestation.PLoS Med. 2022 Jun 23;19(6):e1004029. doi: 10.1371/journal.pmed.1004029. eCollection 2022 Jun. PLoS Med. 2022. PMID: 35737735 Free PMC article. Clinical Trial.
-
3-lead electrocardiogram is more reliable than pulse oximetry to detect bradycardia during stabilisation at birth of very preterm infants.Arch Dis Child Fetal Neonatal Ed. 2018 May;103(3):F233-F237. doi: 10.1136/archdischild-2016-311492. Epub 2017 Jun 30. Arch Dis Child Fetal Neonatal Ed. 2018. PMID: 28667190
-
Respiratory support after delayed cord clamping: a prospective cohort study of at-risk births at ≥35+0 weeks gestation.Arch Dis Child Fetal Neonatal Ed. 2021 Nov;106(6):627-634. doi: 10.1136/archdischild-2020-321503. Epub 2021 Jun 10. Arch Dis Child Fetal Neonatal Ed. 2021. PMID: 34112723 Free PMC article.
-
Novel technologies for heart rate assessment during neonatal resuscitation at birth - A systematic review.Resuscitation. 2019 Oct;143:196-207. doi: 10.1016/j.resuscitation.2019.07.018. Epub 2019 Jul 19. Resuscitation. 2019. PMID: 31330200
-
Delivery room handling of the newborn.J Perinat Med. 2019 Dec 18;48(1):1-10. doi: 10.1515/jpm-2019-0304. J Perinat Med. 2019. PMID: 31834864 Free PMC article. Review.
Cited by
-
Neonatal outcomes and resuscitation practices following the addition of heart rate-guidance to basic resuscitation.PLoS One. 2025 Jan 29;20(1):e0317199. doi: 10.1371/journal.pone.0317199. eCollection 2025. PLoS One. 2025. PMID: 39879181 Free PMC article.
-
Correction: Nerdrum Aagaard et al. Significance of Neonatal Heart Rate in the Delivery Room-A Review. Children2023, 10, 1551.Children (Basel). 2024 Jan 18;11(1):120. doi: 10.3390/children11010120. Children (Basel). 2024. PMID: 38255439 Free PMC article.
-
Immediate heart rate changes in late preterm infants receiving resuscitation in the delivery room.J Perinatol. 2025 Feb 13:10.1038/s41372-025-02220-5. doi: 10.1038/s41372-025-02220-5. Online ahead of print. J Perinatol. 2025. PMID: 39948353 Free PMC article.
-
Threshold to initiate chest compressions for bradycardia at birth: A narrative review.J Perinatol. 2025 Jul;45(7):900-906. doi: 10.1038/s41372-025-02320-2. Epub 2025 May 13. J Perinatol. 2025. PMID: 40360699 Review.
References
-
- Wyckoff M.H., Wyllie J., Aziz K., de Almeida M.F., Fabres J., Fawke J., Guinsburg R., Hosono S., Isayama T., Kapadia V.S., et al. Neonatal Life Support: 2020 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science With Treatment Recommendations. Circulation. 2020;142:S185–S221. doi: 10.1161/CIR.0000000000000895. - DOI - PubMed
-
- Chitkara R., Rajani A.K., Oehlert J.W., Lee H.C., Epi M.S., Halamek L.P. The accuracy of human senses in the detection of neonatal heart rate during standardized simulated resuscitation: Implications for delivery of care, training and technology design. Resuscitation. 2013;84:369–372. doi: 10.1016/j.resuscitation.2012.07.035. - DOI - PubMed
Publication types
LinkOut - more resources
Full Text Sources