Mono- and bi-plane sonographic approach for difficult accesses in the emergency department - A randomized trial
- PMID: 37774550
- DOI: 10.1016/j.ajem.2023.09.018
Mono- and bi-plane sonographic approach for difficult accesses in the emergency department - A randomized trial
Abstract
Background: The insertion of peripheral intravenous (PIV) catheters is one of the most performed invasive procedures in acute healthcare settings. However, peripheral difficult vascular access (PDVA) is not uncommon and can lead to delays in administering essential medications. Ultrasound (US) has emerged as a valuable tool for facilitating PIV cannulation. Advancements in technology have introduced a technique known as bi-plane imaging, allowing the simultaneous display of both longitudinal and transverse views of vessels. We aimed to investigate whether the utilization of bi-plane imaging, as opposed to the single-plane approach, would yield superior results for PDVA in the emergency department (ED).
Methods: This study was a single-center randomized controlled trial. We included adult patients admitted to the ED who required PIV cannulation. Patients were randomly assigned to undergo cannulation using either the mono-plane or bi-plane approach, both performed by skilled providers. The primary outcome of the study was to compare the first attempt success rates between the two techniques.
Results: A total of 442 patients were enrolled, with 221 undergoing cannulation attempts using the mono-plane approach. Successful placement of a functioning PIV catheter was achieved in a single attempt for 313 out of 442 patients (70.8%). There was no significant difference in the success rates between the two study groups: 68.3% in the mono-plane group and 73.3% in the bi-plane group (p = 0.395). The median time required for a successful attempt differed between the groups, with 45 s (range 18-600) in the mono-plane group and 35 s (range 20-600) in the bi-plane group (p = 0.03).
Conclusions: Our study confirms that US is a highly effective tool for facilitating PIV cannulation in patients with PDVA presenting to the ED. However, our investigation into the use of bi-plane imaging did not reveal a significant improvement when compared to mono-plane imaging.
Keywords: Bi-plane imaging; Emergency medicine; Point-of-care ultrasound; Vascular access.
Copyright © 2023 Elsevier Inc. All rights reserved.
Conflict of interest statement
Declaration of Competing Interest None.
Similar articles
-
Evaluating the Accuracy of Point-of-Care Ultrasound for Peripheral Intravenous Cannulation in Emergency and Trauma Patients: A Systematic Review.Cureus. 2025 May 7;17(5):e83625. doi: 10.7759/cureus.83625. eCollection 2025 May. Cureus. 2025. PMID: 40486335 Free PMC article. Review.
-
Ultrasound-Guided Peripheral Intravenous Access Program for Emergency Physicians, Nurses, and Corpsmen (Technicians) at a Military Hospital.Mil Med. 2016 Mar;181(3):272-6. doi: 10.7205/MILMED-D-15-00056. Mil Med. 2016. PMID: 26926753
-
A randomized trial of ultrasound-guided peripheral IV catheter placement in difficult access patients using a guidewire approach.Am J Emerg Med. 2020 Jan;38(1):122-126. doi: 10.1016/j.ajem.2019.07.022. Epub 2019 Jul 17. Am J Emerg Med. 2020. PMID: 31349906 Clinical Trial.
-
Comparison of short-axis out-of-plane versus long-axis in-plane ultrasound-guided radial arterial cannulation in adult patients: a randomized controlled trial.J Anesth. 2017 Feb;31(1):89-94. doi: 10.1007/s00540-016-2270-6. Epub 2016 Oct 19. J Anesth. 2017. PMID: 27761661 Clinical Trial.
-
Ultrasound-guided peripheral intravenous canulation by emergency nurses: A systematic review and meta-analysis.Int Emerg Nurs. 2024 Mar;73:101422. doi: 10.1016/j.ienj.2024.101422. Epub 2024 Feb 23. Int Emerg Nurs. 2024. PMID: 38401479
Cited by
-
Evaluating the Accuracy of Point-of-Care Ultrasound for Peripheral Intravenous Cannulation in Emergency and Trauma Patients: A Systematic Review.Cureus. 2025 May 7;17(5):e83625. doi: 10.7759/cureus.83625. eCollection 2025 May. Cureus. 2025. PMID: 40486335 Free PMC article. Review.
-
Systematic Review of Commercially Available Clinical CMUT-Based Systems for Use in Medical Ultrasound Imaging: Products, Applications, and Performance.Sensors (Basel). 2025 Apr 2;25(7):2245. doi: 10.3390/s25072245. Sensors (Basel). 2025. PMID: 40218757 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources