Laboratory assessment of three new monitors of blood glucose: Accu-Chek II, Glucometer II, and Glucoscan 2000
- PMID: 3779982
Laboratory assessment of three new monitors of blood glucose: Accu-Chek II, Glucometer II, and Glucoscan 2000
Abstract
We describe a laboratory assessment of three new monitors of blood glucose concentrations: the Boehringer "Accu-Chek II" (B), the Ames "Glucometer II" (A), and the Lifescan "Glucoscan 2000" (L). Inherent imprecision (CV) of each monitor was less than 2%. Maximum difference between individual monitors of the same type was less than or equal to 0.5 mmol/L. The volume of blood applied to the test strips is not critical, but duration of blood incubation or color development should be precise. Two types of test strips retained sufficient color 48 h after development to allow checking of the original measurement, and would be suitable as quality-control "spot" checks. Correlation coefficients for results for whole-blood glucose vs those for serum glucose (measured with the Beckman ASTRA-8) were: 0.992 (B), 0.967 (A), and 0.988 (L). Bias plots of these data showed positive bias for A (0.45 mmol/L) and L (0.17 mmol/L) in relation to serum-glucose measurements, but a negative bias of 0.32 mmol/L for B. Calibration solutions are not interchangeable. Although these versions of the monitors are probably not analytically superior to earlier models, they are easier to use.
Similar articles
-
Comparative study of home blood glucose monitoring devices: Visidex, Chemstrip bG, Glucometer, and Accu-Chek bG.Diabetes Care. 1983 Nov-Dec;6(6):529-32. doi: 10.2337/diacare.6.6.529. Diabetes Care. 1983. PMID: 6653308
-
Evaluation of two reagent strips and three reflectance meters for rapid determination of blood glucose concentrations.J Vet Intern Med. 1987 Oct-Dec;1(4):170-4. doi: 10.1111/j.1939-1676.1987.tb02011.x. J Vet Intern Med. 1987. PMID: 3506102
-
Ward and laboratory assessment of two second-generation blood-glucose monitoring systems.Med J Aust. 1988 Oct 17;149(8):420-4. doi: 10.5694/j.1326-5377.1988.tb120702.x. Med J Aust. 1988. PMID: 3173204
-
Self glucose monitoring: a comparison of the Glucometer, Glucoscan, and Hypocount B.Diabetes Care. 1983 May-Jun;6(3):262-7. doi: 10.2337/diacare.6.3.262. Diabetes Care. 1983. PMID: 6347579
-
Maltose interference-free test strips for blood glucose testing at point-of-care: a laboratory performance evaluation.Diabetes Technol Ther. 2010 Nov;12(11):889-93. doi: 10.1089/dia.2010.0095. Epub 2010 Sep 30. Diabetes Technol Ther. 2010. PMID: 20879959
Cited by
-
Blood glucose reagent strip tests in the operating room: influence of hematocrit, partial pressure of oxygen, and blood glucose level--a comparison of the BM-test 1-44, BM-Accutest, and Satellite G reagent strip systems.J Clin Monit. 1996 Jan;12(1):27-33. doi: 10.1007/BF02025307. J Clin Monit. 1996. PMID: 8732813
Publication types
MeSH terms
Substances
LinkOut - more resources
Medical