Cyanoacrylate glue as part of a new bundle to decrease neonatal PICC-related complications
- PMID: 37816981
- DOI: 10.1007/s00431-023-05253-0
Cyanoacrylate glue as part of a new bundle to decrease neonatal PICC-related complications
Abstract
A "bundle" is defined as a combination of evidence-based interventions that, if followed collectively and reliably, improve patient outcomes. The aim of this quasi-experimental study, conducted in a level-III NICU in Belgium, was to assess the impact of central line dressing and maintenance bundle implementation on the rate of catheter-related mechanical complications. We performed a quality improvement (QI) project. Prior to bundle implementation, neonatal PICC lines were secured by Steri-Strip® and occlusive dressing. We implemented a new PICC bundle consisting of the use of glue, sutureless device (Griplock®), and a transparent dressing to secure the catheter to the skin. We compared the rate of infections, mechanical complications, and dislocations before and after bundle implementation (periods 1 and 2, respectively). The use of glue resulted in a significantly decreased rate of central line-associated bloodstream infection (CLABSI) (p < 0.001), dislocations, and mechanical complications (p < 0.0001). During period 2, there was a significant increase for the average number of days the catheter stayed in place (p < 0.05). We did not observe catheter breakage or patient skin irritations attributable to the use of glue (not even in ELBW infants).
Conclusion: The implementation of the new bundle to secure neonatal PICCs in our NICU was associated with a significant reduction in CLABSI and dislodgment rates, without glue-related complications. Active surveillance of CVC placement procedure, positioning, and management, as well as analysis of related complications is crucial for improving patient safety. Continuous implementation of up-to-date central line bundles based on best practice recommendations is a key for quality improvement in NICUs.
What is known: • Stable vascular access is crucial in the NICU. Neonatal PICC securement issues can have serious consequences and are associated with device failure.
What is new: • Catheter securement with tissue adhesive is safe and effective in reducing failure and complication rates in the neonatal population.
Keywords: CLABSI; Central venous catheter; Glue; NICU; Neonate; PICC; Securement.
© 2023. The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature.
References
- 
    - O’Grady NP, Alexander M, Burns LA et al (2011) Guidelines for the prevention of intravascular catheter-related infections. Clin Infect Dis 52(9):e162–e193. https://doi.org/10.1093/cid/cir257 - DOI - PubMed - PMC
 
- 
    - van Rens MF, Spencer TR, Hugill K, Francia AL, van Loon FH, Bayoumi MA (2023) Octyl-butyl-cyanoacrylate glue for securement of peripheral intravenous catheters: a retrospective, observational study in the neonatal population. J Vasc Access 11297298231154629. https://doi.org/10.1177/11297298231154629
 
- 
    - Bahl A, Gibson SM, Jankowski D, Chen NW (2021) Short peripheral intravenous catheter securement with cyanoacrylate glue compared to conventional dressing: a randomized controlled trial. J Vasc Access 11297298211024037. https://doi.org/10.1177/11297298211024037
 
- 
    - Marsh N, Webster J, Flynn J et al (2015) Securement methods for peripheral venous catheters to prevent failure: a randomised controlled pilot trial. J Vasc Access 16(3):237–244. https://doi.org/10.5301/jva.5000348 - DOI - PubMed
 
- 
    - Scoppettuolo G, Dolcetti L, Emoli A, La Greca A, Biasucci DG, Pittiruti M (2015) Further benefits of cyanoacrylate glue for central venous catheterisation. Anaesthesia 70(6):758. https://doi.org/10.1111/anae.13105 - DOI - PubMed
 
MeSH terms