Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Jan;26(1):362-372.
doi: 10.1111/dom.15328. Epub 2023 Oct 12.

Effects of continuous glucose monitoring on glycaemic control in type 2 diabetes: A systematic review and network meta-analysis of randomized controlled trials

Affiliations

Effects of continuous glucose monitoring on glycaemic control in type 2 diabetes: A systematic review and network meta-analysis of randomized controlled trials

Jiaping Lu et al. Diabetes Obes Metab. 2024 Jan.

Abstract

Aims: The aim of this study was to assess the efficacy of continuous glucose monitoring (CGM) versus self-monitoring of blood glucose (SMBG) in maintaining glycaemic control among people with type 2 diabetes mellitus (T2DM).

Materials and methods: The protocol was registered in PROSPERO (CRD42023387583). PubMed, Web of Science, EMBASE and OVID databases were searched from 1 January 2000 until 31 December 2022 for randomized controlled trials comparing CGM with SMBG in glycaemic control among the outpatients with T2DM. The primary endpoint was glycated haemoglobin, while the secondary endpoints included time in range, time below range and time above range. Both traditional and network meta-analyses were conducted to explore the efficacy of CGM on glycaemic control in T2DM.

Results: Eleven high-quality studies, involving 1425 individuals with T2DM, were identified. Traditional meta-analysis revealed that CGM exhibited a significantly decreased [mean difference (MD): -0.31, 95% confidence interval (CI) (-0.45, -0.18)], time above range [MD: -9.06%, 95% CI (-16.00, -2.11)], time below range [MD: -0.30%, 95% CI (-0.49, -0.12)] and a significantly increased time in range [MD: 8.49%, 95% CI (3.96, 13.02)] compared with SMBG. The network meta-analysis showed that real-time CGM can improve the glycaemic control of patients with T2DM to the most extent.

Conclusions: CGM could provide T2DM with greater benefits in glycaemic management compared with SMBG, particularly in patients using real-time CGM. These findings provide an updated perspective on previous research and offer guidance for CGM use in T2DM.

Keywords: continuous glucose monitoring; glycaemic control; network meta-analysis; self-monitoring of blood glucose; type 2 diabetes mellitus.

PubMed Disclaimer

References

REFERENCES

    1. Sun H, Saeedi P, Karuranga S, et al. IDF diabetes atlas: global, regional and country-level diabetes prevalence estimates for 2021 and projections for 2045. Diabetes Res Clin Pract. 2022;183:109119.
    1. Morris AD, Boyle DI, MacAlpine R, et al. The diabetes audit and research in Tayside Scotland (DARTS) study: electronic record linkage to create a diabetes register. DARTS/MEMO Collaboration. BMJ. 1997;315(7107):524-528.
    1. Blevins T. Value and utility of self-monitoring of blood glucose in non-insulin-treated patients with type 2 diabetes mellitus. Postgrad Med. 2013;125(3):191-204.
    1. Teo E, Hassan N, Tam W, Koh S. Effectiveness of continuous glucose monitoring in maintaining glycaemic control among people with type 1 diabetes mellitus: a systematic review of randomised controlled trials and meta-analysis. Diabetologia. 2022;65(4):604-619.
    1. Edelman SV, Argento NB, Pettus J, Hirsch IB. Clinical implications of real-time and intermittently scanned continuous glucose monitoring. Diabetes Care. 2018;41(11):2265-2274.

Publication types

MeSH terms

LinkOut - more resources