Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023:1438:191-195.
doi: 10.1007/978-3-031-42003-0_30.

Observation of Tissue Oxygenation Changes Using Remote Photoplesysmography with a Smartphone

Affiliations

Observation of Tissue Oxygenation Changes Using Remote Photoplesysmography with a Smartphone

Gennadi Saiko et al. Adv Exp Med Biol. 2023.

Abstract

Background: Tissue oxygenation is a critical marker of tissue status and can be used to evaluate and track wound progress, the viability of transplanted tissue, and burns. Thus, the determination of tissue oxygenation (preferably remotely) is of great importance.

Aim: Explore the impact of oxygenation changes on tissue color.

Material and methods: The rPPG of both hands was acquired using a stand-mounted smartphone (iPhone 8) placed about 10 cm above the hands. A 60 s baseline was followed by occlusion of one arm using a cuff inflated to 200 mmHg for approximately 2 min. The cuff was then rapidly deflated, followed by a 60 s recovery period. The reference muscle oxygenation signal (SmO2) was acquired using the near-infrared contact Moxy device (Fortiori Design LLC) placed on the forearm distal to the occlusion. The data were collected on both hands of 28 healthy volunteers.

Results: rPPG can observe changes in tissue oxygenation, which was confirmed across 28 participants using a robust reference standard.

Conclusion: We have an initial confirmation of the notion that rPPG can monitor changes in tissue oxygenation. However, a spectrum of rPPG and SmO2 reductions is observed, which should be explored in future work.

Keywords: Remote photoplesysmography; Smartphone; Tissue oxygenation.

PubMed Disclaimer

References

    1. Venkatesh B, Meacher R, Muller MJ, Morgan TJ, Fraser J (2001) Monitoring tissue oxygenation during resuscitation of major burns. J Trauma Acute Care Surg 50(3):485–494 - DOI
    1. Severinghaus JW, Astrup PB (1986) History of blood gas analysis. IV. Leland Clark’s oxygen electrode. J Clin Monit 2:125–139 - DOI - PubMed
    1. Saiko G, Lombardi P, Au Y, Queen D, Armstrong D, Harding K (2020) Hyperspectral imaging in wound care: a systematic review. Int Wound J 17(6):1840–1856 - DOI - PubMed - PMC
    1. Wukitsch MW, Petterson MT, Tobler DR, Pologe JA (1988) Pulse oximetry: analysis of theory, technology, and practice. J Clin Monit 4(4):290–301 - DOI - PubMed
    1. Burton T, Saiko G, Douplik A (2022) Feasibility study of remote contactless perfusion imaging with consumer-grade mobile camera. Adv Exp Med Biol.;1395:289–293

LinkOut - more resources