. 2023 Dec 15;31(24):1221-1227.
doi: 10.5435/JAAOS-D-23-00043. Epub 2023 Oct 16.

Does Fibular Displacement Predict Tibial Malrotation in Simulated Tibia-Fibula Fractures

Affiliations

Does Fibular Displacement Predict Tibial Malrotation in Simulated Tibia-Fibula Fractures

Abrianna S Robles et al. J Am Acad Orthop Surg. .

Abstract

Introduction: Tibial malrotation can occur with medullary nailing of diaphyseal tibial fractures. Fibular alignment has been proposed as a surrogate for axial plane reduction intraoperatively. The purpose of this study was to determine whether fibular alignment is a reliable marker of accurate tibial rotation.

Methods: Deidentified CT scans of 50 patients with normal tibial anatomy were selected. Using ImageJ software, we simulated osteotomies at three sites (proximal third, mid-diaphysis, and distal third). We overlaid adjacent CT slices and rotated them around the central axis of the tibia in 5° increments of external rotation (ER) and internal rotation (IR). At each increment, measurements of fibular overlap (%) were obtained from anteroposterior (AP) and lateral views. To simulate fixation of the fibula, we repeated rotation around the axis of the fibula with and without a simulated medullary implant in the tibia.

Results: A total of 50 patients were included. The mean age was 62 years, average BMI was 25.8, and 28 of 50 patients (56%) were male. Earliest loss of fibular contact occurred at 24° ER and 22° IR at the proximal site. Contact was lost at 26° ER and 28° IR on the AP view and 42° ER and 29° IR on the lateral view. The mean fibular contact at each 5° increment was similar for ER and IR. Fibular contact was reduced to 50% at 10 to 15° of rotation in ER and IR at all sites. Tibial canal contact was lost at 24° in both ER and IR around the fibula. With a virtual medullary implant, the mean maximal rotation was 6°.

Discussion: Surgeons should be aware that 20° or more of malrotation is likely present when fibular contact is lost during medullary nailing of the tibia. Greater than 50% loss of contact should raise suspicion for malrotation. A fixed fibula and medullary tibial implant theoretically preclude significant tibial malrotation.

PubMed Disclaimer

References

    1. Cain ME, Hendrickx LAM, Bleeker NJ, Lambers KTA, Doornberg JN, Jaarsma RL: Prevalence of rotational malalignment after intramedullary nailing of tibial shaft fractures: Can we reliably use the contralateral uninjured side as the reference standard?. J Bone Joint Surg Am 2020;102:582-591
    1. Say F, Bülbül M: Findings related to rotational malalignment in tibial fractures treated with reamed intramedullary nailing. Arch Orthop Trauma Surg 2014;134:1381-1386
    1. Prasad CV, Khalid M, McCarthy P, O'Sullivan ME: CT assessment of torsion following locked intramedullary nailing of tibial fractures. Injury 1999;30:467-470
    1. Theriault B, Turgeon AF, Pelet S: Functional impact of tibial malrotation following intramedullary nailing of tibial shaft fractures. J Bone Joint Surg Am 2012;94:2033-2039
    1. Clementz BG: Assessment of tibial torsion and rotational deformity with a new fluoroscopic technique. Clin Orthop Relat Res 1989;245:199-209.