Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2023 Oct 5;10(10):1652.
doi: 10.3390/children10101652.

Efficacy of Infrared Vein Visualization versus Standard Technique for Peripheral Venous Cannulation in Infant and Toddler Populations: A Randomized Study

Affiliations

Efficacy of Infrared Vein Visualization versus Standard Technique for Peripheral Venous Cannulation in Infant and Toddler Populations: A Randomized Study

Graham Fehr et al. Children (Basel). .

Abstract

Establishing intravenous (IV) access in younger patient populations via the traditional cannulation technique for procedures requiring anesthesia is often challenging. Infrared (IR) vein visualization is a modality that aids venous cannulation; however, few reports of this technique exist in the infant and toddler population. The primary aim of this study was to compare the efficacy of IR vein visualization to the standard cannulation technique for obtaining peripheral IV access in infant and toddler populations. Following Institutional Review Board (IRB) approval and written informed consent, children were randomly assigned to either a standard cannulation technique group or an IR vein visualization device group for venous cannulation. The primary outcome variable was the success rate of IV cannulation, and the secondary variables were the total number of attempts and the time to successful cannulation. No difference was noted between either group for first-attempt success rate (standard versus IR: 61.25% vs. 54.4%; p = 0.4) or time to establish IV cannulation (standard versus IR: median [interquartile range], 40 s [24-120] vs. 53 s [26-106]; p = 0.55). The anesthesiologist's grading of the anticipated difficulty of IV cannulation was a significant predictor of cannulation success (p = 0.0016). Our study demonstrated no significant benefit in utilizing the IR vein visualization device in terms of the overall success rate, number of attempts, and time to establish successful IV cannulation when compared to the standard technique. However, in difficult IV access situations, this device proved to be a valuable rescue adjunct.

Keywords: anesthesia; infrared vein visualization; intravenous access; toddlers.

PubMed Disclaimer

Conflict of interest statement

The authors declare no conflict of interest.

Figures

Figure 1
Figure 1
CONSORT flow diagram of participants. CONSORT indicates Consolidated Standards of Reporting Trials.

References

    1. Heydinger G., Shafy S.Z., O’Connor C., Nafiu O., Tobias J.D., Beltran R.J. Characterization of the Difficult Peripheral IV in the Perioperative Setting: A Prospective, Observational Study of Intravenous Access for Pediatric Patients Undergoing Anesthesia. Pediatric Health Med. Ther. 2022;13:155–163. doi: 10.2147/PHMT.S358250. - DOI - PMC - PubMed
    1. Kaddoum R.N., Anghelescu D.L., Parish M.E., Wright B.B., Trujillo L., Wu J., Wu Y., Burgoyne L.L. A randomized controlled trial comparing the AccuVein AV300 device to standard insertion technique for intravenous cannulation of anesthetized children. Paediatr. Anaesth. 2012;22:884–889. doi: 10.1111/j.1460-9592.2012.03896.x. - DOI - PubMed
    1. McNeely H.L., Ream T.L., Thrasher J.M., Dziadkowiec O., Callahan T.J. Utilization of a biomedical device (VeinViewer((R))) to assist with peripheral intravenous catheter (PIV) insertion for pediatric nurses. J. Spec. Pediatr. Nurs. 2018;23:e12208. doi: 10.1111/jspn.12208. - DOI - PMC - PubMed
    1. Cuper N.J., de Graaff J.C., Verdaasdonk R.M., Kalkman C.J. Near-Infrared Imaging in Intravenous Cannulation in Children: A Cluster Randomized Clinical Trial. Pediatrics. 2013;131:e191–e197. doi: 10.1542/peds.2012-0968. - DOI - PubMed
    1. De Graaff J.C., Cuper N.J., Mungra R.A.A., Vlaardingerbroek K., Numan S.C., Kalkman C.J. Near-infrared light to aid peripheral intravenous cannulation in children: A cluster randomised clinical trial of three devices. Anaesthesia. 2013;68:835–845. doi: 10.1111/anae.12294. - DOI - PubMed

LinkOut - more resources