. 2023 Dec:112:188-190.
doi: 10.1016/j.sleep.2023.10.024. Epub 2023 Oct 23.

General nomenclature of air leak patterns: A proposal

Affiliations
Free article

General nomenclature of air leak patterns: A proposal

Mathéo Richard et al. Sleep Med. 2023 Dec.
Free article

Abstract

Leakage is a common issue with PAP therapy and may contribute to short-term non-compliance with treatment. PAP manufacturers use different methods to estimate and report air leaks (median, mean, p90, p95, % of important air leak, time spent on major leaks), which makes the analysis and comparisons challenging. Leak intensity is a well-known parameter of major importance as it can significantly affect the performance of PAP devices. However, there is a lack of knowledge regarding another leakage parameter, namely the leakage pattern. As of now, there is no standard classification for leak patterns in real-life settings. Our objective was to develop and propose a comprehensive nomenclature for leakage patterns observed during nasal auto-PAP therapy. We examined 50 ventilatory polygraphy recordings conducted with auto-PAP, based on data from a prior study in which the unintentional leak flow was precisely measured over time. We have categorized leaks into two main types: continuous leaks, which appear and persist for an extended period, and discontinuous leaks, which vanish more rapidly. Continuous leaks can have both abrupt or gradual apparitions and terminations. Their "shape" can be either interrupted or constant. Discontinuous leaks can have both abrupt or gradual apparitions and terminations. Due to the relatively short observation scale (less than 5 min minutes), this type of leakage is not characterized by a specific shape between apparition and termination. This nomenclature could be a valuable tool that facilitates comparative bench tests or clinical studies. This tool could support manufacturers in developing precise algorithms for leak compensation, residual AHI estimation and the accuracy of CPAP monitoring data. Lastly, establishing a standardized approach for describing and categorizing air leakage patterns could assist clinicians in identifying device-related issues, such as patient discomfort arising from specific types of leakage.

PubMed Disclaimer

Conflict of interest statement

Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Lebret Marius reports a relationship with Air Liquide Medical Systems and KerNel Biomedical that includes: employment.