Implant Removal After Medial Opening Wedge High Tibial Osteotomy Provides Implant-Related Pain Relief and Functional Improvement
- PMID: 37949199
- DOI: 10.1016/j.arthro.2023.10.044
Implant Removal After Medial Opening Wedge High Tibial Osteotomy Provides Implant-Related Pain Relief and Functional Improvement
Abstract
Purpose: To investigate the incidence of implant-related pain after medial opening wedge high tibial osteotomy (MOWHTO) using a locking plate, to determine whether implant removal provides pain relief and functional improvement, and to evaluate bone healing and loss of correction after implant removal.
Methods: Between March 2014 and September 2017, MOWHTO was performed without bone graft. The inclusion criteria were patients who underwent implant removal after MOWHTO and were followed up for a minimum of 2 years. Patients were evaluated for implant removal 1 and 2 years after surgery. Clinical and functional evaluations were conducted to investigate implant-related pain using the visual analog scale, Lysholm score, and Tegner score. The radiographic indices measured were the gap-filling rate, weightbearing line (WBL) ratio, hip-knee-ankle angle (HKAA), medial proximal tibial angle (MPTA), and posterior tibial slope angle (PTSA).
Results: A total of 55 patients were enrolled. Fifty-one (92.7%) patients experienced implant-related pain prior to implant removal, with 43 and 8 patients reporting mild pain and moderate pain, respectively. At 1 and 2 years after implant removal, mild pain occurred in 6 (10.9%) and 5 (9.1%) patients, respectively. The remaining patients reported no implant-related pain. Prior to implant removal and 1 year after implant removal, the Lysholm score improved from 77.0 ± 5.6 to 86.8 ± 5.7 (P < .001), and the Tegner score improved from 3.3 ± 1.2 to 3.9 ± 1.3 (P < .001). The mean gap-filling rate was 84.4% ± 9.6% at implant removal, and it significantly increased to 93.7% ± 5.4% and 97.4% ± 2.6% at 1 and 2 years after implant removal, respectively (P < .001). For the WBL ratio, HKAA, MPTA, and PTSA, no statistically significant differences were found after implant removal.
Conclusions: The incidence of implant-related pain after MOWHTO using the medial proximal tibial locking plate was high. Implant removal provides pain relief and functional improvement (met minimal clinically important differences). Even after implant removal, bone healing progressed gradually without a loss of correction in all patients.
Level of evidence: Level IV, case series.
Copyright © 2023 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.
Conflict of interest statement
Disclosures The authors report the following potential conflicts of interest or sources of funding: This research was supported by grant 2020-01 from the Kangdong Sacred Heart Hospital Fund, Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2022R1I1A1A01071458), and Hallym University Research Fund. Full ICMJE author disclosure forms are available for this article online, as supplementary material.
Comment in
-
Editorial Commentary: Locking Plate Removal Is Safe and May Improve Function 1 Year After Medial Opening Wedge High Tibial Osteotomy.Arthroscopy. 2024 Jun;40(6):1845-1847. doi: 10.1016/j.arthro.2024.01.010. Epub 2024 Jan 20. Arthroscopy. 2024. PMID: 38253293
MeSH terms
LinkOut - more resources
Full Text Sources
Research Materials
Miscellaneous