. 2023 Jul 29;7(6):2528-2533.
doi: 10.1016/j.jseint.2023.07.002. eCollection 2023 Nov.

Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy

Collaborators, Affiliations

Remote visual estimation of shoulder range of motion has generally high interobserver reliability but limited accuracy

Simon Hwang et al. JSES Int. .

Abstract

Background: Surgeon visual estimation of shoulder range of motion (ROM) is commonplace in the outpatient office setting and routinely reported in clinical research, but the reliability and accuracy of this practice remain unclear. The purpose of this study is to establish the reliability and accuracy of remote visual estimation of shoulder ROM in healthy volunteers and symptomatic patients among a large group of shoulder surgeons. Our hypothesis is that remote visual estimation would be reliable and accurate compared with the digital goniometer method.

Methods: Fifty shoulder surgeon members of the PacWest Shoulder and Elbow Society independently determined the active shoulder forward flexion (FF), internal rotation at 90° abduction (IR90), external rotation at 90° abduction, external rotation at the side , and maximal spinal level reached with internal rotation (IRspine) through visual estimation of video recordings taken from 10 healthy volunteers and 10 symptomatic patients. Variations in measurements were quantified using the interobserver reliability through calculation of the intraclass correlation coefficient. Accuracy was determined through comparison with digital goniometer measurements obtained with an on-screen protractor application using Bland-Altman mean differences and 95% limits of agreement.

Results: The interobserver reliability among examiners showed moderate to excellent correlation, with intraclass correlation coefficient ranging from 0.768 to 0.928 for the healthy volunteers and 0.739 to 0.878 for the symptomatic patients. Accuracy was limited, with upper limits of agreement exceeding the established minimal clinically important differences (MCIDs) for FF (20° vs. MCID of 14°) and IR90 (25° vs. 18°) in the healthy volunteers and for FF (33° vs. 16°), external rotation at 90° abduction (21° vs. 18°), and IR90 (31° vs. 20°) in the symptomatic patients.

Conclusion: Despite generally high intersurgeon reliability in the visual estimation of shoulder ROM, there was questionable accuracy when compared to digital goniometer measurements,with measurement errors often exceeding established MCID values. Given the potential implications for the clinical response to treatment and the significance of research findings, the adoption of validated instruments to measure ROM and the standardization of examination procedures should be considered.

Keywords: Intraclass correlation coefficient; Shoulder range of motion; Telehealth; Visual estimation; interobserver reliability.

PubMed Disclaimer

Figures

Figure 1
Figure 1
Digital goniometer measurements from a validated, on-screen protractor application. (A) forward flexion. (B) internal rotation at 90° abduction. (C) external rotation at 90° abduction.

References

    1. Atkinson G., Nevill A.M. Statistical methods for assessing measurement error (reliability) in variables relevant to sports medicine. Sports Med. 1998;26:217–238. - PubMed
    1. Bland J.M., Altman D.G. Measuring agreement in method comparison studies. Stat Methods Med Res. 1999;8:135–160. - PubMed
    1. Blonna D., Zarkadas P.C., Fitzsimmons J.S., O'Driscoll S.W. Validation of a photography-based goniometry method for measuring joint range of motion. J Shoulder Elbow Surg. 2012;21:29–35. doi: 10.1016/j.jse.2011.06.018. - DOI - PubMed
    1. Bujang M.A., Baharum N. A simplified guide to determination of sample size requirements for estimating the value of intraclass correlation coefficient: a review. Arch Orofac Sci. 2017;12:1–11.
    1. Buvik A., Bergmo T.S., Bugge E., Smaabrekke A., Wilsgaard T., Olsen J.A. Cost-effectiveness of telemedicine in remote orthopedic consultations: Randomized controlled trial. J Med Internet Res. 2019;21 doi: 10.2196/11330. - DOI - PMC - PubMed

LinkOut - more resources