Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation
. 2024 Jan;36(2):e2309789.
doi: 10.1002/adma.202309789. Epub 2023 Nov 23.

Self-Assembled Nano-CT Contrast Agent Leveraging Size Aggregation for Improved In Vivo Tumor CT Imaging

Affiliations

Self-Assembled Nano-CT Contrast Agent Leveraging Size Aggregation for Improved In Vivo Tumor CT Imaging

Chengcheng Wang et al. Adv Mater. 2024 Jan.

Abstract

Computed tomography (CT) is a widely utilized noninvasive diagnostic tool in clinical practice. However, the commonly employed small molecular iodinated contrast agents (ICAs) in clinical CT imaging have limitations such as nonspecific distribution in body, rapid clearance through kidneys, etc., leading to a narrow imaging time window. In contrast, existing nano-sized ICAs face challenges like structural uncertainty, poor reproducibility, low iodine content, and uniformity issues. In this study, a novel approach is presented utilizing the aggregation-induced emission luminogen (AIEgen) to design and fabricate a kind of monocomponent nano-sized ICA (namely, BioDHU-CT NPs) that exhibits a unique aggregation effect upon activation. The small sized BioDHU-CT nanoparticles exhibit excellent tumor targeting capabilities and can release ICA modified with AIEgen with a high release efficiency up to 88.45%, under the activation of reactive oxygen species highly expressed in tumor regions. The released ICA performs in situ aggregation capability in the tumor region, which can enhance the retention efficiency of CT contrast agents, extending the imaging time window and improving the imaging quality in tumor regions.

Keywords: AIEgen; aggregation function; computed tomography; imaging time window; iodinated contrast agents.

PubMed Disclaimer

Similar articles

Cited by

References

    1. a) J. F. Hainfeld, S. M. Ridwan, Y. Stanishevskiy, N. R. Smilowitz, J. Davis, H. M. Smilowitz, Sci. Rep. 2018, 8, 13803;
    1. b) H. Lusic, M. W. Grinstaff, Chem. Rev. 2013, 113, 1641;
    1. c) X. Meng, H. Zhang, M. Zhang, B. Wang, Y. Liu, Y. Wang, X. Fang, J. Zhang, Z. Yao, W. Bu, Adv. Sci. 2019, 6, 1901214;
    1. d) J. Zhang, W. Liu, P. Zhang, Y. Song, Z. Ye, H. Fu, S. Yang, Q. Qin, Z. Guo, J. Zhang, ACS Biomater. Sci. Eng. 2022, 8, 32;
    1. e) Y. Zou, Y. Wei, G. Wang, F. Meng, M. Gao, G. Storm, Z. Zhong, Adv. Mater. 2017, 29, 1603997.

MeSH terms

LinkOut - more resources